Boilers 283
Features
- 150,000 BTU input - 125,000 BTU heating capacity - 82.6% AFUE - Probe type low water cut off - Insulated jacket - 391 Square feet of steam
- 6 inch flue - 2 inch feed and return - 1/2 inch gas inlet - Cast iron heat exchanger - Blocked vent and roll out safety switch
- Pressure high limit - Intermittent pilot control - Stainless steel burners - Integral draft hood - Automatic vent damper
- Can be converted to LP with LP conversion kit
Features
- Adjusts for LP or Natural Gas - NO Field Conversion Kits
- Built-In Primary/Secondary LABOR SAVER(TM) Manifold
- 7:1 Turndown Modulation Ratio in DHW Mode
- 5.7:1 Turndown Modulation Ratio in Heating Mode
- Warranty Coverage
- FREE 2-Year Parts & Labor Limited Warranty
- 10-Year Limited Heat Exchanger
- Built by American Craftsman
Features
- 112,000 BTU input - 93,000 BTU heating capacity - 82.4% AFUE - Probe type low water cut off - Insulated jacket - 292 Square feet of steam
- 5 inch flue - 2 inch feed and return - 1/2 inch gas inlet - Cast iron heat exchanger - Blocked vent and roll out safety switch
- Pressure high limit - Intermittent pilot control - Stainless steel burners - Integral draft hood - Automatic vent damper
- Can be converted to LP with LP conversion kit
Features
- 22,000 BTU input to 125,000 BTU input - 113,000 BTU heating capacity - 95.0% AFUE - Energy Star Rated - Heating only - Does not include circulator
- 3 inch PVC, CPVC or Polypropylene flue pipe - Requires boiler adapter kit - Automatically recognizes Natural Gas or LP
- Stainless Steel Heat Exchanger - Electrical connections at bottom of boiler - 3/4 inch copper supply and return connections
- Stainless steel mesh modulating burner - Intermittent direct spark ignition - Includes low water cut off
- Fully removable jacket front - Includes condensate drain with built in trap - Easy programming with text display
- Wall Hung - Multiple boiler functionality - Outdoor temperature sensor included - LCD status display - Flame sensor
Features
- 29,500 BTU input to 164,000 BTU input - 153,000 BTU heating capacity - 95.0% AFUE - Energy Star Rated - Heating only - Does not include circulator
- 3 inch PVC, CPVC or Polypropylene flue pipe - Requires boiler adapter kit - Automatically recognizes Natural Gas or LP
- Stainless Steel Heat Exchanger - Electrical connections at bottom of boiler - 1 inch copper supply and return connections
- Stainless steel mesh modulating burner - Intermittent direct spark ignition - Includes low water cut off
- Fully removable jacket front - Includes condensate drain with built in trap - Easy programming with text display
- Wall Hung - Multiple boiler functionality - Outdoor temperature sensor included - LCD status display - Flame sensor
Features
- 29,500 BTU input to 164,000 BTU input in heating only mode - 153,000 BTU heating capacity - 95.0% AFUE - Energy Star Rated - Does not include circulator
- 29,500 BTU input to 205,000 BTU input in domestic hot water mode - 153,000 BTU heating capacity
- Domestic hot water has stainless steel heat exchanger and 5 gallon per minute recovery at 70 degrees
- 3 inch PVC, CPVC or Polypropylene flue pipe - Requires boiler adapter kit - Automatically recognizes Natural Gas or LP
- Stainless Steel Heat Exchanger - Electrical connections at bottom of boiler - 3/4 inch copper supply and return connections
- Stainless steel mesh modulating burner - Intermittent direct spark ignition - Includes low water cut off
- Fully removable jacket front - Includes condensate drain with built in trap - Easy programming with text display
- Wall Hung - Multiple boiler functionality - Outdoor temperature sensor included - LCD status display - Flame sensor
Features
- 187,000 BTU input - 156,000 BTU heating capacity - 82.8% AFUE - Probe type low water cut off - Insulated jacket - 488 Square feet of steam
- 7 inch flue - 2 inch feed and return - 3/4 inch gas inlet - Cast iron heat exchanger - Blocked vent and roll out safety switch
- Pressure high limit - Intermittent pilot control - Stainless steel burners - Integral draft hood - Automatic vent damper
- Can be converted to LP with LP conversion kit
Features
- 36,000 to 241,000 BTU input - 216,000 BTU heating capacity - 95% AFUE - Energy Star Rated - Built in circulator
- 3 inch CPVC or Polypropylene flue pipe - Can be used with LP without a conversion kit
- Stainless Steel Heat Exchanger - All connections at bottom of boiler - 1 inch copper or ProPress supply and return connections with included manifold
- User interface with LCD text and graphical screen display - Wall mounted - Multiple boiler functionality
Features
- 299,000 BTU input - 250,000 BTU heating capacity - 83.4% AFUE - Probe type low water cut off - Insulated jacket - 782 Square feet of steam
- 7 inch flue - 2 inch feed and return - 3/4 inch gas inlet - Cast iron heat exchanger - Blocked vent and roll out safety switch
- Pressure high limit - Intermittent pilot control - Stainless steel burners - Integral draft hood - Automatic vent damper
- Can be converted to LP with LP conversion kit
Features
- 75,000 BTU input - 62,000 BTU heating capacity - 82.2% AFUE - Probe type low water cut off - Insulated jacket - 195 Square feet of steam
- 5 inch flue - 2 inch feed and return - 1/2 inch gas inlet - Cast iron heat exchanger - Blocked vent and roll out safety switch
- Pressure high limit - Intermittent pilot control - Stainless steel burners - Integral draft hood - Automatic vent damper
- Can be converted to LP with LP conversion kit
Features
- 263,000 BTU input - 219,000 BTU heating capacity - 83.2% AFUE - Probe type low water cut off - Insulated jacket - 685 Square feet of steam
- 7 inch flue - 2 inch feed and return - 3/4 inch gas inlet - Cast iron heat exchanger - Blocked vent and roll out safety switch
- Pressure high limit - Intermittent pilot control - Stainless steel burners - Integral draft hood - Automatic vent damper
- Can be converted to LP with LP conversion kit
Features
- 35,000 to 379,000 BTU input - 348,000 BTU heating capacity - 95% Thermal Efficiency - Energy Star Rated - Built in circulator
- 4 inch CPVC or Polypropylene flue pipe - Can be used with LP without a conversion kit
- Stainless Steel Heat Exchanger - All connections at bottom of boiler - 1-1/2 inch copper or ProPress supply and return connections with included manifold
- User interface with LCD text and graphical screen display - Floor mounted - Multiple boiler functionality
Features
- 224,000 BTU input - 193,000 BTU heating capacity - 85.0% AFUE - Primary, high limit and circulator controls - Beckett AFG Burner
- 7 inch flue - 2 inch feed - 1-1/2 inch return - 1-1/4 inch circulator connection - Cast iron heat exchanger - Includes Taco circulator
- Swing open burner door - Target wall - Textured painted steel jacket - No coil opening
Features
- 140,000 BTU input - 122,000 BTU heating capacity - 86.0% AFUE - Primary, high limit and circulator controls - Beckett AFG Burner
- 6 inch flue - 2 inch feed - 1-1/2 inch return - 1-1/4 inch circulator connection - Cast iron heat exchanger - Includes Taco circulator
- Swing open burner door - Target wall - Textured painted steel jacket - No coil opening
Features
- 20,000 to 100,000 BTU input - 91,000 BTU heating capacity - 95.0% AFUE - Energy Star Rated - Does not include circulator
- 2 inch or 3 inch PVC, CPVC or Polypropylene flue pipe - Includes LP conversion kit
- Stainless Steel Heat Exchanger - Electrical connections at bottom of boiler - 1-1/4 inch Supply and return connections on bottom of boiler
- Stainless steel mesh modulating burner - Intermittent direct spark ignition - Includes probe type low water cut off
- Fully removable jacket front - Includes condensate drain with built in trap - Easy programming with text display
- Wall Hung - Multiple boiler functionality - Outdoor temperature sensor included - LCD status display - Flame sensor
Features
- 225,000 BTU input - 188,000 BTU heating capacity - 83.0% AFUE - Probe type low water cut off - Insulated jacket - 587 Square feet of steam
- 7 inch flue - 2 inch feed and return - 3/4 inch gas inlet - Cast iron heat exchanger - Blocked vent and roll out safety switch
- Pressure high limit - Intermittent pilot control - Stainless steel burners - Integral draft hood - Automatic vent damper
- Can be converted to LP with LP conversion kit
Features
- 231,000 BTU input - 201,000 BTU heating capacity - 86.0% AFUE - Hydrolevel Fuel Smart control - Low water cut off - Beckett AFG Burner - Energy Star Rated
- 6 inch flue for chimney venting - 1-1/4 inch feed and return - Cast iron heat exchanger with 3 pass design - Includes Taco circulator
- Reversible swing open burner door - Target wall - Textured painted steel jacket - Digital user display interface with dial type limit settings