DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water content - Beckett AFG oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
Boilers 283
If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 104,000 BTU heating capacity - 86.2% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 126,000 BTU heating capacity - 85.0% AFUE - 12 gallons water content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE - If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water content - Beckett AFG oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE - If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water content - Carlin EZ1HP oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 104,000 BTU heating capacity - 86.2% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 126,000 BTU heating capacity - 85.0% AFUE - 12 gallons water content - Carlin EZ1HP oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water content - Carlin EZ1HP oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
If boiler is fired at 1.75 gallons per hour: 245,000 BTU input - 212,000 BTU heating capacity - 85.5% AFUE - If boiler is fired at 1.95 gallons per hour: 273,000 BTU input - 235,000 BTU heating capacity - 85.0% AFUE - 17.75 gallons water content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
Features
- If boiler is fired at 2.00 gallons per hour: 280,000 BTU input 235,000 BTU heating capacity - 85.0% AFUE
- If boiler is fired at 1.75 gallons per hour: 245,000 BTU input - 212,000 BTU heating capacity - 85.5% AFUE - Beckett AFG oil burner
- Cast iron sections - Deluxe Classic powder coated steel jacket - Boiler reset control with Low Water Cut Off - Taco 007 circulator
- Full plate swing out burner door - Top flue outlet - Top cleanout - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water content - Riello F5 oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE - If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water content - Carlin EZ1HP oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 104,000 BTU heating capacity - 86.2% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 126,000 BTU heating capacity - 85.0% AFUE - 12 gallons water content - Riello F5 oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
Features
- 42,000 to 199,000 BTU input - 185,000 BTU heating capacity - 95.0% AFUE - Energy Star Rated
- Stainless Steel Heat Exchanger - Electrical Connections at top of Boiler
- Stainless steel burners - Direct spark ignition - Connection for Low Water Cut Off
- Fully removable jacket front - Condensate System with Neutralizer
- Wall Hung - Can be floor mounted - Adjustable boiler legs
- LCD status display - Dual Flame Sensors - Multiple boiler functionality
Features
- 80,000 to 399,000 BTU input - 380,000 BTU heating capacity - 95.2% Thermal Efficiency
- Stainless Steel Heat Exchanger - Supply and Return on side of boiler - Can be converted to LP with included LP Kit
- Multiple Temperature Operation with Domestic Hot Water Priority - Spark ignition - Connection for Low Water Cut Off
- Fully removable jacket front - Condensate System with Neutralizer
- Adjustable boiler legs - Cascade Capable - High Temperature Vent Limit Switch
- LCD status display - Dual Flame Sensors - Equipped for Outdoor Reset Operation with Included Outdoor Sensor
DOE 2021 compliant - If boiler is fired at .75 gallons per hour: 105,000 BTU input - 92,000 BTU heating capacity - 86.5% AFUE - If boiler is fired at 1.00 gallon per hour: 140,000 BTU input - 121,000 BTU heating capacity - 85.5% AFUE - 17.40 gallons water content - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Probe type low water cut off - Skim tapping - Pressure control - Tankless opening with cover plate
DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water content - Riello F5 oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE - If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
Features
- If boiler is fired at 1.50 gallons per hour: 210,000 BTU input 179,000 BTU heating capacity - 84.3% AFUE - Tankless coil
- If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 151,000 BTU heating capacity - 85.4% AFUE - Beckett AFG oil burner
- Cast iron sections - Deluxe Classic powder coated steel jacket - Probe type Low Water Cut Off - Pressure control
- Full plate swing out burner door - Top or Rear flue outlet - Top cleanout - Built in air elimination baffle
- Gauge glass and gauge cocks
* OIL W/BECKETT - TANKLESS COIL INSTALLED
PEER ECTE03SPTL STM BLR 1603029
* OIL W/BECKETT & TANKLESS COIL INSTALLED - VENT SIZE: 6"
GPH: 0.75 * INPUT: 105,000 * OUTPUT WATER: 93,000 * OUTPUT STEAM: 92,000
GPH: 1.00 * INPUT: 175,000 * OUTPUT WATER: 122,000 * OUTPUT STEAM: 121,000
GPH: 0.75 NET MBH: WATER= 81,000 STEAM= 69,000
GPH: 1.00 NET MBU: WATER= 106,000 STEAM= 91,000
AFUE GPH: 0.75 (WATER): 87.6 * (STEAM) 86.5
AFUE GPH: 1.00 (WATER): 86.5 * (STEAM) 85.5
DIMENSIONS: (HxWxD) 42" x 22-1/2" x 15-3/4"
FEATURES: UP TO 87.6 AFUE, ALL MODELS DOE 2021 COMPLIANT, NATURAL DRAFT,
CAST IRON, LARGE WATER CONTENT, WET BASE SECTION DESIGN,
POWDER COATED STEEL JACKET, SWING-OUT DOOR, OPTIONAL TANKLESS COILS.
LIFETIME WARRANTY: All residential cast iron boilers include a full
one-year warranty. A limited, lifetime warranty is provided for the cast
iron sections of Peerless residentail hot water boilers. A limited,
ten-year warranty is provided on the cast iron sections of residentail
steam boilers.
------------------------------REVISED 05/2/22 NSOARES
DOE 2021 compliant - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 104,000 BTU heating capacity - 325 square feet of steam - 85.6% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 396 square feet of steam- 85.0% AFUE - 12 gallons water content - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle - Probe type low water cut off - Skim tapping - Pressure control
DOE 2021 compliant - If boiler is fired at .75 gallons per hour: 105,000 BTU input - 92,000 BTU heating capacity - 86.5% AFUE - If boiler is fired at 1.00 gallon per hour: 140,000 BTU input - 121,000 BTU heating capacity - 85.5% AFUE - 17.40 gallons water content - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Probe type low water cut off - Skim tapping - Pressure control - Tankless opening with cover plate
DOE 2021 compliant - If boiler is fired at .85 gallons per hour: 119,000 BTU input - 104,000 BTU heating capacity - 85.6% AFUE - If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 85.0% AFUE - 12 gallons water content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle - Probe type low water cut off - Skim tapping - Pressure control
Features
- If boiler is fired at 1.05 gallons per hour: 147,000 BTU input 124,000 BTU heating capacity - 83.6% AFUE
- If boiler is fired at 0.85 gallons per hour: 119,000 BTU input - 103,000 BTU heating capacity - 84.8% AFUE - Beckett AFG oil burner
- Cast iron sections - Deluxe Classic powder coated steel jacket - Probe type Low Water Cut Off - Pressure control
- Full plate swing out burner door - Top or Rear flue outlet - Top cleanout - Built in air elimination baffle
- Gauge glass and gauge cocks
DOE 2021 compliant - If boiler is fired at 1.75 gallons per hour: 245,000 BTU input - 214,000 BTU heating capacity - 86.6% AFUE - If boiler is fired at 1.95 gallons per hour: 273,000 BTU input - 237,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water content - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 152,000 BTU heating capacity - 85.4% AFUE - If boiler is fired at 1.50 gallon per hour: 210,000 BTU input - 181,000 BTU heating capacity - 85.5% AFUE - 17.40 gallons water content - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Probe type low water cut off - Skim tapping - Pressure control - Tankless opening with cover plate
If boiler is fired at 1.75 gallons per hour: 245,000 BTU input - 212,000 BTU heating capacity - 85.5% AFUE - If boiler is fired at 1.95 gallons per hour: 273,000 BTU input - 235,000 BTU heating capacity - 85.0% AFUE - 17.75 gallons water content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
Features
- 20,000 to 80,000 BTU input - 75,000 BTU heating capacity - 95.0% AFUE - Energy Star Rated
- Stainless Steel Heat Exchanger - Electrical Connections at top of Boiler
- Stainless steel burners - Direct spark ignition - Connection for Low Water Cut Off
- Fully removable jacket front - Condensate System with Neutralizer
- Wall Hung - Can be floor mounted - Adjustable boiler legs
- LCD status display - Dual Flame Sensors - Multiple boiler functionality
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE - If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water content - Riello F5 oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE - If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE - If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
If boiler is fired at 1.75 gallons per hour: 245,000 BTU input - 212,000 BTU heating capacity - 85.5% AFUE - If boiler is fired at 1.95 gallons per hour: 273,000 BTU input - 235,000 BTU heating capacity - 85.0% AFUE - 17.75 gallons water content - Carlin 99 oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section design - Full plate swing out burner door - Top flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
Features
- 118,000 BTU input - 99,000 BTU heating capacity - 83.5% AFUE Efficiency
- Knocked down boiler - Cast iron sections - Deluxe powder coated jacket - Automatic vent damper
- Reset control with Low Water Cut Off - Spark ignition - Does not come with circulator - Can be converted to LP using LP kit
- Flame rollout safety shutoff switch - Blocked vent switch - Horizontal to vertical draft diverter
Old Number 1303017
Features
- 105,000 BTU input to 154,000 BTU input - 131,000 BTU heating capacity - Tankless Coil - 84.1% AFUE
- Boiler is shipped with 0.75, 0.85, and 1.10 oil nozzles - Beckett NX oil burner - Cast iron sections - Deluxe powder coated jacket
- Boiler reset control with Low Water Cut Off - Taco 007 circulator - Built in air elimination baffle
- Full plate swing out burner door - Top flue outlet - Top cleanout - Concentric vent termination kit - 10 foot flexible vent pipe kit
Features
- If boiler is fired at 2.25 gallons per hour: 385,000 BTU input - 321,000 BTU heating capacity - 84.4% Combustion efficiency
- If boiler is fired at 2.50 gallons per hour: 420,000 BTU input - 347,000 BTU heating capacity - 83.7% Combustion efficiency
- The boiler is shipped knocked down and with both nozzles, and has the 2.50 nozzle installed - Beckett CF-375 oil burner
- Cast iron sections - Deluxe Classic powder coated steel jacket - Pressure control - Gauge glass and Gauge cocks
- Full plate swing out burner door - Top flue outlet - Side cleanout - Draft regulator - Tankless Opening with Cover Plate
Features
- If boiler is fired at 1.50 gallons per hour: 245,000 BTU input - 212,000 BTU heating capacity - 85.6% AFUE
- If boiler is fired at 1.75 gallons per hour: 280,000 BTU input - 240,000 BTU heating capacity - 84.6% AFUE
- If boiler is fired at 2.00 gallons per hour: 350,000 BTU input - 286,000 BTU heating capacity - 85.1% Combustion efficiency
- The boiler is shipped knocked down and with all 3 nozzles, and has the 1.75 nozzle installed - Beckett AFG oil burner
- Cast iron sections - Deluxe Classic powder coated steel jacket - Pressure control - Gauge glass and Gauge cocks
- Full plate swing out burner door - Top flue outlet - Side cleanout - Draft regulator - Tankless Opening with Cover Plate
Features
- If boiler is fired at 2.25 gallons per hour: 385,000 BTU input - 321,000 BTU heating capacity - 84.4% Combustion Efficiency
- If boiler is fired at 2.50 gallons per hour: 420,000 BTU input - 347,000 BTU heating capacity - 83.7% Combustion Efficiency
- The boiler is shipped knocked down and with all 3 nozzles, and has the 2.50 nozzle installed - Beckett CF-375 oil burner
- Cast iron sections - Deluxe Classic powder coated steel jacket - Boiler reset control with Hydrolevel 3250 Low Water Cut Off
- Full plate swing out burner door - Top flue outlet - Side cleanout - Draft regulator - Tankless Opening with Cover Plate - Less circulator
Features
- If boiler is fired at 1.50 gallons per hour: 245,000 BTU input - 214,000 BTU heating capacity - 86.2% AFUE
- If boiler is fired at 1.75 gallons per hour: 280,000 BTU input - 241,000 BTU heating capacity - 85.2% AFUE
- If boiler is fired at 2.00 gallons per hour: 350,000 BTU input - 286,000 BTU heating capacity - 85.1% Combustion Effieciency
- The boiler is shipped knocked down and with all 3 nozzles, and has the 1.75 nozzle installed - Beckett AFG oil burner
- Cast iron sections - Deluxe Classic powder coated steel jacket - Boiler reset control with Hydrolevel 3250 Low Water Cut Off
- Full plate swing out burner door - Top flue outlet - Side cleanout - Draft regulator - Tankless Opening with Cover Plate - Less circulator