Circulator Pumps 418
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate - Proportional pressure control - Constant pressure control - Constant curve/constant speed - Internal motor protection - Wide temperature range where the liquid temperature and the ambient temperature are independent of each other - LED control indicator
Single stage, close coupled, volute pump with in line suction and discharge ports of identical diameter. The pump is of the top pull out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Pipework connection is via 150 psi ANSI flanges (not included). The pump is fitted with a fan cooled, permanent magnet synchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is fitted with a combined temperature and differential pressure sensor.
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
Single stage, close coupled, volute pump with in line suction and discharge ports of identical diameter. The pump is of the top pull out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Pipework connection is via 150 psi ANSI flanges (not included). The pump is fitted with a fan cooled, permanent magnet synchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is fitted with a combined temperature and differential pressure sensor.
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
3 phase - Flange mount - This pump features a VLS pump, MLE motor and integrated variable frequency drive and control, all made by one supplier. Together with various sensors, these products allow for dynamic and intelligent solutions to many industrial and commercial building applications. The innovative solution cuts planning, purchasing, installation and commissioning costs.The integrated variable frequency motor (MLE) is available with permanent magnet motors and exceeds IE5 efficiency levels set by International Electro Technical Commission, currently the highest efficiency worldwide for electrical motors. NEMA Premium Efficient motors are equivalent to IE3, meaning these MLE motors are two levels above NEMA Premium Efficiency. The combined motor and VFD efficiency is higher than a NEMA Premium motor alone.The VLSC features a VLS pump with a Grundfos CUE variable frequency drive and control
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
3 phase - Flange mount - This pump features a VLS pump, MLE motor and integrated variable frequency drive and control, all made by one supplier. Together with various sensors, these products allow for dynamic and intelligent solutions to many industrial and commercial building applications. The innovative solution cuts planning, purchasing, installation and commissioning costs.The integrated variable frequency motor (MLE) is available with permanent magnet motors and exceeds IE5 efficiency levels set by International Electro Technical Commission, currently the highest efficiency worldwide for electrical motors. NEMA Premium Efficient motors are equivalent to IE3, meaning these MLE motors are two levels above NEMA Premium Efficiency. The combined motor and VFD efficiency is higher than a NEMA Premium motor alone.The VLSC features a VLS pump with a Grundfos CUE variable frequency drive and control
Single stage, close coupled, volute pump with in line suction and discharge ports of identical diameter. The pump is of the top pull out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Pipework connection is via 150 psi ANSI flanges (not included). The pump is fitted with a fan cooled, permanent magnet synchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is fitted with a combined temperature and differential pressure sensor.
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate - Proportional pressure control - Constant pressure control - Constant curve/constant speed - Internal motor protection - Wide temperature range where the liquid temperature and the ambient temperature are independent of each other - LED control indicator
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
2 pole motor - The pump is of the top pull out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is fitted with a fan-cooled asynchronous motor.
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
4 pole motor- Double head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
4 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
Must be installed with the motor shaft in a horizontal position - 1-1/4 inch Male Union Connections - Two pole PSC motor
2 pole motor - The pump is of the top pull out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is fitted with a fan-cooled asynchronous motor.
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
4 pole motor- Single head circulator - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel bearing plate and rotor cladding - AutoAdapt proportional pressure control - FlowAdapt and FlowLimit used in systems where a flow limitation is required - Intuitive user interface with TFT display - Constant pressure control - Constant temperature control - Built in differential pressure and temperature sensor - Constant curve duty - Maximum or minimum curve duty - Automatic Night Setback - Internal motor protection - Heat energy meter - Work log history - Insulating shells supplied with single head pumps for heating systems - Large temperature range where the liquid temperature and the ambient temperature are independent of each other
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor
4 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
2 pole motor - Pumps are of the canned rotor type, meaning that the pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. - Stainless steel rotor can, bearing plate and rotor cladding - Stator housing in aluminum alloy can be turned to change the position of the terminal box - Stator housing has 8 drain holes (that must point downwards) to allow condensed water to escape - Stator with built in thermal overload switch.
Must be installed with the motor shaft in a horizontal position - A 50% glycol antifreeze solution will reduce the circulator performance by approximately 15% - Two pole PSC motor