Wirsbo hePEX features an oxygen barrier that conforms to DIN 4726 for use in closed-loop hydronic piping and radiant heating and cooling applications. The tubing is rated and listed by the Hydrostatic Stress Board of PPI at 200 deg F at 80 psi, 180 deg F at 100 psi and 73.4 deg F at 160 psi. It is compatible with Uponor ProPEX and QS-style fittings and is manufactured in full compliance to ASTM F876 and F877. It is also listed to NSF 61 for potable-water applications.
Uponor Wirsbo® hePEX™ Tubing, 5/16 in Nominal Size, 0.292 in Inside Dia, 0.43 in Outside Dia, 1000 ft Coil Length, 80 to 160 psi Working, 73.4 to 200 deg F, PEX-A, White
Uponor AquaPEX® tubing is used in hot and cold water distribution systems and AquaSAFE™ residential fire safety systems. Uponor AquaPEX® tubing is suitable for use in hydronic heating applications where the system contains no ferrous corrodible components or where any ferrous components are isolated from the tubing. Uponor AquaPEX® tubing coils and straight lengths come in red, white and blue for potable-water applications, and purple for water-reclamation applications. Uponor AquaPEX® tubing is manufactured and listed to ASTM F876 and F877 and CSA B137.5, certified to NSF Standards 14 and 61 and listed by the Hydrostatic Stress Board of PPI at 200 deg F at 80psi, 180 deg F at 100psi and 73.4 deg F at 160psi. Uponor AquaPEX® white tubing (1/2", 3/4", 1" and 1-1/4" only) is also listed to UL 1821 and ULC/ORD C199P and carries an additional rating of 120 deg F at 130psi. Uponor AquaPEX® red and blue tubing is marked with the PEX 5206 designation as required by the most recent edition of ASTM F876-15a, indicating it exceeds ASTM F876 chlorine-resistance requirements for continuous-recirculation systems operating up to 140 deg F while also affording a 90-day UV-resistance level.
Uponor AquaPEX® Tubing, 3/4 in Nominal Size, 0.671 in Inside Dia, 7/8 in Outside Dia, 100 ft Coil Length, 80 to 160 psi Working, 73.4 to 200 deg F, PEX, Red
Approved for use in hot or cold potable water distibution - Approved for use in hydronic heating or cooling applications if the system
contains no ferrous corrodible components - Not approved for use in Uponor AquaSAFE systems
Wirsbo hePEX(TM) features an oxygen barrier that conforms to DIN 4726 for use in closed-loop hydronic piping and radiant heating and cooling applications. The tubing is rated and listed by the Hydrostatic Stress Board of PPI at 2000-degree F (93.3-degree C) at 80psi, 180-degree F (82.2-degree C) at 100psi and 73.4-degree F (23-degree C) at 160psi. It is compatible with Uponor ProPEX and QS-style fittings and is manufactured in full compliance to ASTM F876 and F877. It is also listed to NSF 61 for potable-water applications.
Pipe shall be manufactured from virgin rigid ABS (acrylonitrile butadiene styrene) compounds with a cell class of 42222 as identified in ASTM D 3965. Fittings shall be manufactured from virgin rigid ABS compounds with a cell class of 32222 as identified in ASTM D 3965. ABS cellular core pipe shall be Iron Pipe Size (IPS) conforming to ASTM F 628. Injection molded ABS DWV fittings shall conform to ASTM D 2661. All systems shall utilize a separate waste and vent system. All pipe and fittings shall be manufactured in the united states. Pipe and fittings shall conform to NSF International Standard 14.
Charlotte DWA Foam Core Pipe, 3 in Nominal, Plain, 3-1/2 in Outside Dia, 10 ft Length, 0.216 in Wall Thickness, SCH 40/STD, ABS, Black, ASTM F628, NSF Approved
Uponor AquaPEX® tubing is used in hot and cold water distribution systems and AquaSAFE™ residential fire safety systems. Uponor AquaPEX® tubing is suitable for use in hydronic heating applications where the system contains no ferrous corrodible components or where any ferrous components are isolated from the tubing. Uponor AquaPEX® tubing coils and straight lengths come in red, white and blue for potable-water applications, and purple for water-reclamation applications. Uponor AquaPEX® tubing is manufactured and listed to ASTM F876 and F877 and CSA B137.5, certified to NSF Standards 14 and 61 and listed by the Hydrostatic Stress Board of PPI at 200 deg F at 80psi, 180 deg F at 100psi and 73.4 deg F at 160psi. Uponor AquaPEX® white tubing (1/2", 3/4", 1" and 1-1/4" only) is also listed to UL 1821 and ULC/ORD C199P and carries an additional rating of 120 deg F at 130psi.
Uponor AquaPEX® Tubing, 1-1/4 in Nominal Size, 1.104 in Inside Dia, 1-3/8 in Outside Dia, 20 ft Straight Length, 80 to 160 psi Working, 73.4 to 200 deg F, PEX, White
Clear vinyl hose applications include: air conditioning and refrigeration condensate drains, condensate pump discharge lines and humidifier overflows.
Diversitech Drain Line Tubing, Accessory Type: Drain Line Tubing, 100 ft L, 0.5 in ID x 0.631 in OD, 0.066 in THK, Vinyl, Clear, Domestic
PVC SCH 40/STD is highly durable, with high tensile and impact strength. It is easy to install and has better sound deadening qualities than PVC SCH 40/STD DWV Foam Core. Installation requires the use of primer and solvent cement. For DWV applications, gradual sloping DWV fittings must be used.
Charlotte Foam Core Pipe, 1-1/2 in Nominal, Plain, 1.9 in Outside Dia, 20 ft Length, 0.145 in Wall Thickness, SCH 40/STD, PVC, White, ASTM F891, NSF Approved, Domestic
PVC SCH 40/STD is highly durable, with high tensile and impact strength. It is easy to install and has better sound deadening qualities than PVC SCH 40/STD DWV Foam Core. Installation requires the use of primer and solvent cement. For DWV applications, gradual sloping DWV fittings must be used.
Charlotte Foam Core Pipe, 1-1/2 in Nominal, Plain, 1.9 in Outside Dia, 20 ft Length, 0.145 in Wall Thickness, SCH 40/STD, PVC, White, ASTM F891, NSF Approved, Domestic
Uponor AquaPEX® tubing is used in hot and cold water distribution systems and AquaSAFE™ residential fire safety systems. Uponor AquaPEX® tubing is suitable for use in hydronic heating applications where the system contains no ferrous corrodible components or where any ferrous components are isolated from the tubing. Uponor AquaPEX® tubing coils and straight lengths come in red, white and blue for potable-water applications, and purple for water-reclamation applications. Uponor AquaPEX® tubing is manufactured and listed to ASTM F876 and F877 and CSA B137.5, certified to NSF Standards 14 and 61 and listed by the Hydrostatic Stress Board of PPI at 200 deg F at 80psi, 180 deg F at 100psi and 73.4 deg F at 160psi. Uponor AquaPEX® white tubing (1/2", 3/4", 1" and 1-1/4" only) is also listed to UL 1821 and ULC/ORD C199P and carries an additional rating of 120 deg F at 130psi.
Uponor AquaPEX® Tubing, 1/2 in Nominal Size, 0.475 in Inside Dia, 5/8 in Outside Dia, 20 ft Straight Length, 80 to 160 psi Working, 73.4 to 200 deg F, PEX, White
7-58 is designed for air conditioning and refrigeration condensate drains, condensate pump discharge lines and humidifier overflows. Made of high-quality vinyl with smooth interior and exterior that allows easy flow and flushing and prevents sediment accumulation. Its walls are thick enough to resist kinks but are lightweight, flexible, can withstand rough handling, and heavy usage while maintaining dimensional stability. Easy to shape, bend, and install.
Diversitech Drain Line Tubing, Accessory Type: Drain Line Tubing, 100 ft L, 0.625 in ID x 0.771 in OD, 0.073 in THK, Vinyl, Clear, Domestic
Aquatherm blue pipe is specifically engineered for applications beyond potable water installations. It offers a tougher, longer lasting, more environmentally responsible solution to other non-potable pressure systems.
In addition to the general advantages of the PP-R pipe system, Aquatherm blue pipe offers higher volumetric flow rates due to thinner walls and is high-heat stabilized for short exposures to temperatures beyond the intended design. PP-R piping is also extremely resistant to impact, corrosion, and seismic stresses.
Aquatherm blue pipe uses the same socket fittings and tools as Aquatherm green pipe, making installation simple and easy. The dimensions range from 1/2" to 24" ND. Aquatherm blue pipe is also available with UV protection for outdoor installations and faser-composite (MF) technology, which reduces linear expansion.
Uponor AquaPEX® white tubing is suitable for use in hydronic heating applications where the system contains no ferrous corrodible components or where any ferrous components are isolated from the tubing. Uponor AquaPEX® white tubing is manufactured and listed to ASTM F876 and F877 and CSA B137.5, certified to NSF Standards 14 and 61 and listed by the Hydrostatic Stress Board of PPI at 200 deg F at 80psi, 180 deg F at 100psi and 73.4 deg F at 160psi. Uponor AquaPEX® tubing (1/2", 3/4", 1" and 1-1/4" only) is also listed to UL 1821 and ULC/ORD C199P and carries an additional rating of 120 deg F at 130psi. Uponor AquaPEX® white tubing is marked with the PEX 5106 designation as required by the most recent edition of ASTM F876-15a, indicating it exceeds ASTM F876 chlorine-resistance requirements for continuous-recirculation systems operating up to 140 deg F while also affording a 30-day UV-resistance level.
Uponor AquaPEX® Tubing, 1 in Nominal Size, 0.862 in Inside Dia, 1-1/8 in Outside Dia, 300 ft Coil Length, 80 to 160 psi Working, 73.4 to 200 deg F, PEX, White
Uponor AquaPEX® tubing is used in hot and cold water distribution systems and AquaSAFE™ residential fire safety systems. Uponor AquaPEX® tubing is suitable for use in hydronic heating applications where the system contains no ferrous corrodible components or where any ferrous components are isolated from the tubing. Uponor AquaPEX® tubing coils and straight lengths come in red, white and blue for potable-water applications, and purple for water-reclamation applications. Uponor AquaPEX® tubing is manufactured and listed to ASTM F876 and F877 and CSA B137.5, certified to NSF Standards 14 and 61 and listed by the Hydrostatic Stress Board of PPI at 200 deg F at 80psi, 180 deg F at 100psi and 73.4 deg F at 160psi. Uponor AquaPEX® white tubing (1/2", 3/4", 1" and 1-1/4" only) is also listed to UL 1821 and ULC/ORD C199P and carries an additional rating of 120 deg F at 130psi. Uponor AquaPEX® red and blue tubing is marked with the PEX 5206 designation as required by the most recent edition of ASTM F876-15a, indicating it exceeds ASTM F876 chlorine-resistance requirements for continuous-recirculation systems operating up to 140 deg F while also affording a 90-day UV-resistance level.
Uponor AquaPEX® Tubing, 1/2 in Nominal Size, 0.475 in Inside Dia, 5/8 in Outside Dia, 100 ft Coil Length, 80 to 160 psi Working, 73.4 to 200 deg F, PEX, Red
Uponor's pre-insulated PEX pipe offering complies with ASHRAE 90.1-2013 and the 2012 International Energy Conservation Code (IECC). The pipe is available in 1/2" to 2" configurations with 1/2", 1", 11/2" and 2" insulation that features manufactured sealed seams that run the entire length of the coil. Check with local code authorities regarding energy-code requirements for specific applications.