For use as a hub in a boiler room - 1-1/2 inch main run with four 1 inch male zone connections - 7 inch space between zone connections -
Thread protectors on all outlets
For use as a hub in a boiler room - 1-1/2 inch main run with six 1 inch male zone connections - 7 inch space between zone connections -
Thread protectors on all outlets
For use as zone manifold, radiant manifold, return manifold and boiler headers in a boiler room - 1-1/4 inch sweat 6 foot long main run with
twelve 3/4 inch sweat zone connections - Zone connections are on 6 inch centers - Type "L" copper tubing
For use as a hub in a boiler room - 1-1/2 inch main run with four 3/4 inch male zone connections - 7 inch space between zone connections -
Thread protectors on all outlets
For use as a hub in a boiler room - 1-1/4 inch main run with five 3/4 inch male zone connections - 7 inch space between zone connections -
Thread protectors on all outlets
Stainless manifolds are to be used in closed loop hydronic heating, cooling and snow melting system. These preassembled 1-1/4" diameter stainless supply and return manifolds come attached to two 6-5/8" spacing brackets for compact remote mounting. This stainless manifold provides shut off and balancing valves for each circuit. Manifolds used with flow rates up to 2 gpm per circuit, maximum of 18 gpm per manifold. The air bleeder and purge valve are connected and factory tested. 1-1/4" Union connection, 1" NPT removable end caps. SVC Circuit connection fittings are sold separately.
Stainless manifolds are to be used in closed loop hydronic heating, cooling and snow melting system. These preassembled 1-1/4" diameter stainless supply and return manifolds come attached to two 6-5/8" spacing brackets for compact remote mounting. This stainless manifold provides shut off and balancing valves for each circuit. Manifolds used with flow rates up to 2 gpm per circuit, maximum of 18 gpm per manifold. The air bleeder and purge valve are connected and factory tested. 1-1/4" Union connection, 1" NPT removable end caps. SVC Circuit connection fittings are sold separately.
For use as zone manifold, radiant manifold, return manifold and boiler headers in a boiler room - 1-1/4 inch sweat 6 foot long main run with
eighteen 3/4 inch sweat zone connections - Zone connections are on 4 inch centers - Type "L" copper tubing
Stainless manifolds are to be used in closed loop hydronic heating, cooling and snow melting system. These preassembled 1-1/4" diameter stainless supply and return manifolds come attached to two 6-5/8" spacing brackets for compact remote mounting. This stainless manifold provides shut off and balancing valves for each circuit. Manifolds used with flow rates up to 2 gpm per circuit, maximum of 18 gpm per manifold. The air bleeder and purge valve are connected and factory tested. 1-1/4" Union connection, 1" NPT removable end caps. SVC Circuit connection fittings are sold separately.
Extra strong, expertly cast iron is at the heart of Ward Fittings quality. From laboratory to foundry, raw materials undergo strict metallurgical and processing controls, chemical analysis and inspection to produce closely grained, high-tensile, non-porous iron. Generations of expertise and rigorous quality control results in durable yet precise cast and malleable iron fittings and components that meet or exceed national and industry standards - and the needs of contractors around the world who believe that down to the last detail, quality counts.
Ward Mfg WARDFlex® Manifold Bracket Assembly, Steel, Domestic
For use as zone manifold, radiant manifold, return manifold and boiler headers in a boiler room - 1-1/4 inch sweat 6 foot long main run with
twelve 1 inch sweat zone connections - Zone connections are on 6 inch centers - Type "L" copper tubing
The EP Heating Manifold Assemblies feature isolation valves and balancing valves with flow meters, and come fully assembled, ready for installation. The manifolds are available in 2- through 8-loop configurations with a maximum flow of 15.4 gpm. The body ends feature R32 unions and the loop outlets have R20 male threads. The manifold mounts on a bracket (A2670006) that comes with the assembly.
Not for potable water - For 1-1/4 inch x 1 inch threaded system piping - For boilers with external circulators - Includes: 1 - hot and cold
double boiler drain manifold, 1 - 1-1/4 inch female adapter with valve, 1 - fully fabricated and insulated flexible supply and return lines with 1
inch female fitting, 1 - rigid copper line, 1 - 30 PSI pressure gauge, 1 - 30 PSI pressure relief valve, and 1 - 3/4 inch female service valve kit
with 150 PSI pressure relief valve