Honeywell VR8200C-1041/U 1/2 inch x 1/2 inch Standing Pilot Step Opening Natural Gas Valve
Item SKU - VR8200C1041/U by Honeywell
EDP - 972964
Product Description
Old Number VR8200C-1041
Single stage - 24 Volt - Step Opening - 130,000 BTU per hour at 1 inch water column - 20,000 BTU per hour minimum - 200,000 BTU per hour maximum
Easy to install, adjust and service; all adjustments and connections are accessible from top of control - LP conversion kit is not available
Provides two automatic valves: Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends - Diaphragm operated second automatic valve opens under control of regulator and closes if gas or power supply is interrupted
Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure
Meets codes requiring dual safety shutoff - Complete safety shutoff on pilot flame failure - LITE-RITE (OFF-PILOT-ON) lighting sequence
Documentation
Specifications
These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).
Approximate Weight (pounds)
Honeywell VR8200C-1041/U 1/2 inch x 1/2 inch Standing Pilot Step Opening Natural Gas Valve
Item SKU - VR8200C1041/U by Honeywell (EDP 972964)
Product Description
Old Number VR8200C-1041
Single stage - 24 Volt - Step Opening - 130,000 BTU per hour at 1 inch water column - 20,000 BTU per hour minimum - 200,000 BTU per hour maximum
Easy to install, adjust and service; all adjustments and connections are accessible from top of control - LP conversion kit is not available
Provides two automatic valves: Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends - Diaphragm operated second automatic valve opens under control of regulator and closes if gas or power supply is interrupted
Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure
Meets codes requiring dual safety shutoff - Complete safety shutoff on pilot flame failure - LITE-RITE (OFF-PILOT-ON) lighting sequence
Documentation
Specifications
These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).
Approximate Weight (pounds) |
|