Rheem®, R951V0403A17M4SCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 42000 Btu/hr Input, 39900 Btu/hr Output, 115 V, 95 % AFUE, 990 cfm Flow Rate, Natural Gas, Multi 4 Way Furnace Position, Low NOX: No, ECM Variable Speed Motor, 1/2 hp Motor, 1/2 in Connection, Direct Spark Ignition, 34 in H x 17.5 in W x 29.63 in D Dimensions, Domestic
Rheem®, R921V0603A17M4SCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 56000 Btu/hr Input, 53200 Btu/hr Output, 115 V, 92 % AFUE, 1100 cfm Flow Rate, Natural Gas, Multi 4 Way Furnace Position, Low NOX: No, ECM Variable Speed Motor, 1/2 hp Motor, 1/2 in Connection, Direct Spark Ignition, 34 in H x 17.5 in W x 29.63 in D Dimensions, Domestic
Rheem®, R921V0855A21M4SCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 84000 Btu/hr Input, 79800 Btu/hr Output, 115 V, 92 % AFUE, 1735 cfm Flow Rate, Natural Gas, Multi 4 Way Furnace Position, Low NOX: No, ECM Variable Speed Motor, 1 hp Motor, 1/2 in Connection, Direct Spark Ignition, 34 in H x 21 in W x 29.63 in D Dimensions, Domestic
Rheem®, R801V1255A24UHSCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 125000 Btu/hr Input, 100000 Btu/hr Output, 115 V, 80 % AFUE, 1900 cfm Flow Rate, Natural Gas, Horizontal/Upflow Furnace Position, Low NOX: No, ECM Variable Speed Motor, 3/4 hp Motor, 1/2 in Connection, Direct Spark Ignition, Aluminized Steel, 34 in H x 24.5 in W x 29.59 in D Dimensions, Domestic
Rheem®, R921V1155A24M4SCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 112000 Btu/hr Input, 106400 Btu/hr Output, 115 V, 92 % AFUE, 1650 cfm Flow Rate, Natural Gas, Multi 4 Way Furnace Position, Low NOX: No, ECM Variable Speed Motor, 1 hp Motor, 1/2 in Connection, Direct Spark Ignition, 34 in H x 24.5 in W x 29.63 in D Dimensions, Domestic
Rheem®, R951V1005A21M4SCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 98000 Btu/hr Input, 93100 Btu/hr Output, 115 V, 95 % AFUE, 1440 cfm Flow Rate, Natural Gas, Multi 4 Way Furnace Position, Low NOX: No, ECM Variable Speed Motor, 1 hp Motor, 1/2 in Connection, Direct Spark Ignition, 34 in H x 21 in W x 29.63 in D Dimensions, Domestic
Rheem®, R951V0603A17M4SCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 56000 Btu/hr Input, 53200 Btu/hr Output, 115 V, 95 % AFUE, 1100 cfm Flow Rate, Natural Gas, Multi 4 Way Furnace Position, Low NOX: No, ECM Variable Speed Motor, 1/2 hp Motor, 1/2 in Connection, Direct Spark Ignition, 34 in H x 17.5 in W x 29.63 in D Dimensions, Domestic
Rheem®, R951V0703A17M4SCAP, Gas Furnace, 1-Stage, Series: Line Classic®, 70000 Btu/hr Input, 66500 Btu/hr Output, 115 V, 95 % AFUE, 1200 cfm Flow Rate, Natural Gas, Multi 4 Way Furnace Position, Low NOX: No, ECM Variable Speed Motor, 1/2 hp Motor, 1/2 in Connection, Direct Spark Ignition, 34 in H x 17.5 in W x 29.63 in D Dimensions, Domestic
Rheem®, RCFY3624MTANMC, Line Cooling Coil, Cased, 3 ton Nominal, Multi-Position Air Flow, R-454B Refrigerant, 3/8 in Liquid Line, 7/8 in Suction Line, 32.5 in H x 24.5 in W x 21.69 in D Dimensions
Rheem®, 51-106543-00, AC Motor, Motor Blower Application, 1 hp, 120 V, 11.1 A, 60 Hz Frequency, 1050 rpm Speed, 48Y Frame, 1/2 in Dia Shaft, Reversible Rotation, Ball Bearing, Shell-Band Mounting, 5-39/64 in Dia x 12-7/16 in L Dimensions
Rheem®, RP14AY18AJ1NA, Heat Pump, 1-Stage, 1.5 ton Nominal, 18000 Btu/hr Heating, 17.1 to 54.5 kBtu/hr Cooling, R-454B Refrigerant, 1/7 hp Motor, 1075 rpm, 73 dBA Sound Level, 25 in H x 29.75 in W x 29.75 in L Dimensions
Rheem®, 51-106541-17, AC Motor, Blower Application, 1/2 hp, 120 V, 5.8 A, 60 Hz Frequency, 1050 rpm Speed, 48Y Frame, 1/2 in Dia Shaft, Reversible Rotation, Ball Bearing, Shell-Band Mounting, 5-39/64 in Dia x 11-13/16 in L Dimensions
Rheem®, R801T0753A17DZSNAS, Gas Furnace, 1-Stage, Series: Line Classic®, 75000 Btu/hr Input, 60000 Btu/hr Output, 115 V, 80 % AFUE, Natural Gas, Downflow Furnace Position, Low NOX: No, Constant Torque Motor, 3/4 hp Motor, 1/2 in Connection, Direct Spark Ignition, Aluminized Steel, 34.75 in H x 17.5 in W x 28.81 in D Dimensions, Domestic
Rheem®, 51-106543-25, AC Motor, Blower Application, 1 hp, 120 V, 11.1 A, 60 Hz Frequency, 1050 rpm Speed, 48Y Frame, 1/2 in Dia Shaft, Reversible Rotation, Ball Bearing, Shell-Band Mounting, 5-39/64 in Dia x 12-9/16 in L Dimensions
Rheem®, R801T0503A14DZSNAS, Gas Furnace, 1-Stage, Series: Line Classic®, 50000 Btu/hr Input, 40000 Btu/hr Output, 115 V, 80 % AFUE, Natural Gas, Downflow Furnace Position, Low NOX: No, Constant Torque Motor, 1/2 hp Motor, 1/2 in Connection, Direct Spark Ignition, Aluminized Steel, 34.75 in H x 14 in W x 28.81 in D Dimensions, Domestic
Why use a Commercial Achiever air cooled condensing unit? The size allows you to mix or match components to meet
actual job requirements, thus eliminating the need to use oversized or undersized equipment. Equipment sized to meet the
actual load will provide better operating economy, better humidity control, and longer equipment life. With an air cooled system,
you have no water or sewer connections to make, and no troublesome and costly water treatment problems. Since the
condensing unit is located outside the building, and the low profile air handling unit can be installed in the drop ceiling or in
the conditioned space, you will not need a separate equipment room which takes up valuable building space. Remote mounting
of the already quiet condensing unit keeps the compressor and condenser fan noise outside, and the vertical discharge fans
carry the sound up and away from the surrounding area. Because of the simple design of the Ruud remote condensing unit,
installation is quick and simple, and very little maintenance is required.
Features
All cabinet access panels can be opened or removed without affecting the structural strength of the unit. Stamped
louvered panels offer 100% protection for the condenser coil.
Lug for field connection of ground wire
208 / 230 volt, 60 hertz , 3 phase
-The contactor is an electrical switch which operates the compressor and outdoor fans. Its 24 volt coil is activated
on a call for cooling or heating.
75 VA step down transformer, from line volts to 24 volts with resetable circuit breaker
Auto reset high pressure control and auto reset low pressure control provides compressor protection under abnormally
high head pressure conditions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure conditions
(restrictions, TEV failure, loss of charge, indoor blower failure, etc.) while eliminating nuisance tripping sometimes
experienced with conventional control systems.
The coil is constructed with copper tubes and aluminum fins mechanically bonded to tubes for maximum heat transfer
capabilities. All coil assemblies are leak tested up to 550 PSIG (3792 kPa) internal pressure.
The control box with separate line and control voltages, as well as compressor and other refrigerant controls are accessible
through access panels. An electrical access cover may be opened or removed without affecting normal operation of the unit.
Condenser fan motors are equipped with molded plugs for easy removal. Louver panels and end access panel can be
removed for coil cleaning.
The base pan is galvanized steel with weather resistant baked enamel finish
The Scroll Compressor is hermetically sealed with internal high temperature protection, and durable insulation on
motor windings. The entire compressor is mounted on rubber grommets to reduce vibration and noise.
Suction line accumulator to prevent liquid slugging of the compressor
All sweat joint refrigerant connections are made external of the unit and are located close to the ground for a neat
looking installation
Service valves are standard on liquid line and vapor line