The Weatherking WH1P Air handler is designed with a sturdy steel cabinet with one inch of foil faced insulation, offering excellent
thermal and sound insulation, which means you get quiet and efficient comfort. The WH1P Air Handler adjusts airflow in the home to help
control humidity. Airflow can be set for specific needs so your home feels just the way you want it. The factory installed indoor aluminum
cooling coil is the key component for your air handler. The coil is essential to humidity control and improved system performance. The new
lanced fin design also provides maximum performance and increased efficiency. The high grade condensate drain pan keeps the unit
operating smoothly and the corrosion resistant aluminum endplates keep the unit looking as good as it runs.
Features
This is a multiposition air handler: Upflow, downflow, horizontal right or horizontal left
Supply dimensions: 10-5/16 inches front to back - 16 inches side to side - Supply duct flanges are standard
Return dimensions: 19-3/4 inches front to back - 15-7/8 inches side to side
Can be used with air conditioners
The most compact unit design available
Attractive, rugged steel wall cabinet with pre-painted exterior
1 inch of foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance
Four leg motor mount
Slide out blower housing with motor, blower and controls for service and maintenance convenience
Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing
Molded polymer corrosion resistant condensate drain pan
Expansion valve on indoor coil provides for operation with air conditioning
WeatherKing Indoor Furnace cased coils and replacement uncased coils are designed for use with WeatherKing outdoor units and are
available for vertical upflow or downflow, and horizontal left or horizontal right airflow.
Features
This is a multiposition coil
Plenum dimensions: 19-7/8 inches front to back - 23-1/2 inches side to side - Flanges are provided for field installation
Can be used on gas or oil furnaces, but cannot be used on 14 wide oil furnaces and cannot be installed as horizontal left application on
any oil furnace
Coils are tested at the factory with an extensive refrigerant leak check
Constructed of aluminum fins bonded to internally grooved aluminum tubing
Copper sweat refrigerant connections
Coils feature two sets of 3/4 inch condensate drain connections for ease of connection
Unique drain pan design maximizes application flexibility and condensate removal
Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal set material
Compatible with Germicidal UV Resistant Light System
Bi-directional air flow eliminates the need to switch any internal components from horizontal left to right
Chatleff metering device connections at inlet and outlet of TXV and equalizer connections
"N" coil design maximizes performance and minimizes height required at installation
WeatherKing Indoor Furnace cased coils and replacement uncased coils are designed for use with WeatherKing outdoor units and are
available for vertical upflow or downflow, and horizontal left or horizontal right airflow.
Features
This is a multiposition coil
Plenum dimensions: 19-7/8 inches front to back - 20 inches side to side - Flanges are provided for field installation
Can be used on gas or oil furnaces, but cannot be used on 14 wide oil furnaces and cannot be installed as horizontal left application on
any oil furnace
Coils are tested at the factory with an extensive refrigerant leak check
Constructed of aluminum fins bonded to internally grooved aluminum tubing
Copper sweat refrigerant connections
Coils feature two sets of 3/4 inch condensate drain connections for ease of connection
Unique drain pan design maximizes application flexibility and condensate removal
Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal set material
Compatible with Germicidal UV Resistant Light System
Bi-directional air flow eliminates the need to switch any internal components from horizontal left to right
Chatleff metering device connections at inlet and outlet of TXV and equalizer connections
"N" coil design maximizes performance and minimizes height required at installation
WeatherKing Indoor Furnace cased coils and replacement uncased coils are designed for use with WeatherKing outdoor units and are
available for vertical upflow or downflow, and horizontal left or horizontal right airflow.
Features
This is a multiposition coil
Plenum dimensions: 19-7/8 inches front to back - 16-1/2 inches side to side - Flanges are provided for field installation
Can be used on gas or oil furnaces, but cannot be used on 14 wide oil furnaces and cannot be installed as horizontal left application on
any oil furnace
Coils are tested at the factory with an extensive refrigerant leak check
Constructed of aluminum fins bonded to internally grooved aluminum tubing
Copper sweat refrigerant connections
Coils feature two sets of 3/4 inch condensate drain connections for ease of connection
Unique drain pan design maximizes application flexibility and condensate removal
Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal set material
Compatible with Germicidal UV Resistant Light System
Bi-directional air flow eliminates the need to switch any internal components from horizontal left to right
Chatleff metering device connections at inlet and outlet of TXV and equalizer connections
"N" coil design maximizes performance and minimizes height required at installation
WeatherKing Indoor Furnace cased coils and replacement uncased coils are designed for use with WeatherKing outdoor units and are
available for vertical upflow or downflow, and horizontal left or horizontal right airflow.
Features
This is a multiposition coil
Plenum dimensions: 19-7/8 inches front to back - 13 inches side to side - Flanges are provided for field installation
Can be used on gas or oil furnaces, but cannot be used on 14 wide oil furnaces and cannot be installed as horizontal left application on
any oil furnace
Coils are tested at the factory with an extensive refrigerant leak check
Constructed of aluminum fins bonded to internally grooved aluminum tubing
Copper sweat refrigerant connections
Coils feature two sets of 3/4 inch condensate drain connections for ease of connection
Unique drain pan design maximizes application flexibility and condensate removal
Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal set material
Compatible with Germicidal UV Resistant Light System
Bi-directional air flow eliminates the need to switch any internal components from horizontal left to right
Chatleff metering device connections at inlet and outlet of TXV and equalizer connections
"N" coil design maximizes performance and minimizes height required at installation
All RGEA models feature Scroll compressors for maximum efficiency and quiet operation. Our gas / electric package units feature a tubular
heat exchanger design. Tubular heat exchangers are more efficient and durable than older style clamshell heat exchangers.
Features
This unit is shipped ready for horizontal installation, but can be converted to side or down discharge
Scroll compressor for maximum efficiency and quiet operation
Louvered condenser compartment to protect the coil against yard hazards and weather extremes
One piece top with a drip flange to help keep water out of the unit
Supply and return air openings feature a one inch tall flange to prevent water migration into the ductwork
Access panels have weep holes and channels to further help manage water run off
Easily accessible blower section complete with a slide out blower
Conviently located refrigerant connections
Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper
tube / aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing
potential. It is easier to clean and has a more robust surface.
Inside the easily accessible furnace compartment is the draft inducer motor. This motor is specially designed for quiet reliable operation. In
addition to the draft inducer motor, the in-shot gas burners and manifold efficiently regulate the flow of gas for combustion. These gas / electric
units also feature direct spark ignition and remote flame sensors for added reliability and efficiency
Easily accessible control box
Tubular heat exchanger
Standard filter drier
Rugged base rail is standard equipment
Molded compressor plugs
A double sloped evaporator coil drain pan assures all water is removed from the unit to improve indoor air quality.
The Ruud Commercial Achiever RKNL furnace / air conditioner package features convertible air flow, forkable base rails, permanently
lubricated evaporator, condenser and gas heat inducer motors and much more
Features
This is a convertible airflow furnace / air conditioner package; vertical down flow or horizontal side flow
2 two stage Scroll compressors
Single slab, single pass designed evaporator and condenser coils
Foil faced insulation encapsulated throughout the entire unit
TXV refrigerant metering system on each circuit
Hinged major access door with heavy duty gaskets and quarter turn latches
Two stage gas valve with direct spark ignition system, solid state furnace controls and optimized induced draft combustion
Solid core liquid line filter drier
Tubular heat exchanger
Copper tubing / aluminum fin coils
Condenser motors are internally protected and totally enclosed with shaft down design
24 volt control system with resettable circuit breakers
Internally sloped slide out condensate pan
High pressure and low pressure / loss of charge protection
Color coded and labeled wiring
Forkable base rails for easy handling and lifting
High performance belt drive motor with variable pitch pulleys and quick adjust belt system