Skip to main content

Contact our sales team for more information 860-221-SALE

Honeywell

Item SKU - ZD16X18/U

EDP - 842600

Out of stock

Old Number ZD16X18

Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.

Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades

Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24-volt spring return motor.

Fail safe, normally open operation

Honeywell

Item SKU - MV876B1018

EDP - 868344

Out of stock

Fits F76S and F74C Filters

This control is fitted to the drain valve and is programmed by the user to automatically perform the backwash function according to the desired interval.

Bayonet fitting simplifies upgrade to automatic backwash - 16 field selectable backwash intervals (from every four minutes to once every three months) eliminate need for external timer.

Connections for external control provide for use in automated systems and differential pressure control.

Can be manually activated to initiate backwash - Battery (AA) backup to ensure completion of backwash cycle in spite of power loss

Honeywell

Item SKU - V5013N1063/U

EDP - 693550

Out of stock

The V5013N is a three-way threaded globe valve that controls hot water, cold water, and glycol solutions (up to 50 percent concentration), in heating or cooling HVAC applications. The valves direct flow from one or two inlets to a common outlet. Honeywell Globe Valve, 3-Way Mixing, Series: V5013N, 1 in Nominal, FNPT, 217 psi at 248 deg F Safe Operating, 150 lb, 36 to 248 deg F Water Ambient, Red Brass Body, Stainless Steel Trim, PTFE/EPDM Packing, 7-5/16 in H x 4-1/16 in W, Domestic

Honeywell

Item SKU - TH5320C-1002/U

EDP - 842434

Case Quantity - 12

Out of stock

Old Number TH5320C-1002

Easy access battery replacement - Displays in 2.98 square inch standard backlit screen - Conventional systems and heat pumps

Precise comfort control which maintains consistent comfort - Dual powered; battery and/or hard wired - 3 wire communicating

Automatic or manual changeover - Horizontal mount

Honeywell

Item SKU - VNT5150H1000/U

EDP - 1034134

Out of stock

Eliminates the need for overhead ducting - Balance without adjusting dampers - Polypropylene 10 inch HRV Core

Removable Duct Collars - Damperless Balancing - Adjustable Hanging Straps - Centralized Wiring and Speed Control

Customizable - Compact Size - 150 Cubic feet per minute airflow

Honeywell

Item SKU - AM101-1LF/U

EDP - 1033961

Out of stock

Old Number AM101-1LF

Operating Temperature from 70 Degrees to 145 Degrees - 3/4 inch FIPS - Teflon Coated, Nickle Plated Lead Free Brass Body

Teflon Coated Lead Free Brass Shuttle - EPDM Rubber "O" Rings

Honeywell

Item SKU - ZD12X20/U

EDP - 708041

Out of stock

Old Number ZD12X20

Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.

Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades

Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24-volt spring return motor.

Fail safe, normally open operation

Honeywell

Item SKU - SPRD10/U

EDP - 395170

Out of stock

Old Number SPRD10

Single blade, steel barometric damper used to bypass excess air when majority of zone dampers are closed

Counter balanced weighted arm to control bypass air for zoned systems

Air pressure in duct system increases as zone dampers close, pushing the SPRD open automatically

Arm and weight both adjustable to control amount of air bypassed - Recommended for low pressure systems with less than 0.5 in. wc

For larger systems and tighter pressure control, use MARD damper and static pressure controller (SPC)

Honeywell

Item SKU - T6051A-1016/U

EDP - 350359

Out of stock

Old Number T6051A-1016

Used to control fan coils, fans, motor starters, valves, contactors, and circulator motors in heating and or cooling systems

Use with Q651A or Q651B subbases for system and fan switching - Can be used for heating or cooling; if used for heating and cooling a manual switch must be used

Removable setpoint knob locks setpoint and prevents tampering - With locking cover - Single pole, double throw (SPDT) switching

Honeywell

Item SKU - R8184G-4074/U

EDP - 335457

Case Quantity - 20

Out of stock

Old Number R8184G-4074

Provides automatic, non-recycling control of an intermittent ignition oil burner system.

Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat - Solid state flame sensing circuit.

LED on terminal strip indicates system lockout - 30 second safety lockout - Enclosed safety switch with external reset button.

Manual trip lever opens safety switch for system maintenance - Mounts on standard 4 x 4 inch junction box or directly on the burner

Honeywell

Item SKU - M835A-1051/U

EDP - 335446

Case Quantity - 4

Out of stock

Old Number M835A-1051

Zone motor used with two wire, 24 Volt room thermostat or other controller for two position damper control

Controls zone or changeover damper in heating and air conditioning systems, and control gates on feeders.

Single pole single throw (SPST) end switch makes within 20 seconds of full open, breaks within 20 seconds after start of closing stroke.

Foot mounted - Spring return

Honeywell

Item SKU - TH3110D1008/U

EDP - 916423

Case Quantity - 12

Out of stock

Old Number TH3110D-1008

Horizontal mounting - Heat pump compatible if no auxillary heat

Backlit digital display - Current and set temperatures are easy to read in various lighting conditions

Precise comfort control maintains consistent comfort to the highest level of accuracy

Basic operation - Easy to use slide switches allow selection of the heat or cool mode, and operate the fan

Manual switchover from heating to cooling

Honeywell

Item SKU - V4046A1074/U

EDP - 335437

Case Quantity - 20

Out of stock

Old Number V4046A-1074

Power interruption closes the valve immediately - Delayed opening - Mounts directly to pipeline or on support bracket

Two 36 inch lead wires - 120 Volts

Honeywell

Item SKU - T675A-1565/U

EDP - 692792

Out of stock

Old Number T675A-1565

Used to control dampers and valves in heating, cooling and heating/cooling systems - Copper bulb with 20 foot capillary - Includes duct bulb holder

Controller can be mounted in any position - Single pole, double throw (SPDT) switching

3 degree to 10 degree differential - 125 degree maximum operating temperature

Honeywell

Item SKU - AQ1000TP2/U

EDP - 946016

Out of stock

Old Number AQ1000TP2

Controls the ambient air or floor temperature in hydronic heating applications. To provide zoning control, it communicates with and is powered by a Honeywell AQ2000 series zoning module.

Two wire polarity insensitive - Seven day programmable - Network communicating - User buttons feature liquid crystal display, as well as outdoor, indoor, and

Floor temperature displays. Selectable temporary and permanent backlight

Honeywell

Item SKU - ZD18X14/U

EDP - 736986

Out of stock

Old Number ZD18X14

Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.

Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades

Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24 volt spring return motor

Fail safe, normally open operation

Honeywell

Item SKU - T675A-1045/U

EDP - 811471

Out of stock

Old Number T675A-1045

Used to regulate temperature of air or liquids in ducts, pipes, tanks and boilers - Stainless steel bulb with 20 foot capillary

Controller can be mounted in any position - Single pole, double throw (SPDT) switching

3 degree to 10 degree differential - 125 degree maximum operating temperature

Honeywell

Item SKU - ZD6X8/U

EDP - 840963

Out of stock

Old Number ZD6X8

Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.

Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades

Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24 volt spring return motor

Fail safe, normally open operation

Honeywell

Item SKU - YTH5230R-1017/U

EDP - 915426

Case Quantity - 6

Out of stock

Old Number YTH5320R-1017

Includes: one TH5320R-1002/U Wireless FocusPRO Non-Programmable Thermostat, one C7735A-1000/U Return Air Sensor, one THM5320R-1000/U Equipment Interface Module, one C7089R-1013/U wireless outdoor sensor, and one REM5000R-1001/U personal comfort station

RedLINK compatible - 2 heat and 2 cool stages for conventional systems - 3 heat and 2 cool stages for heat pumps - Automatic or manual changeover

Honeywell

Item SKU - YTHX9321R-1001/U

EDP - 915421

Case Quantity - 4

Out of stock

Old Number YTHX9321R-1000

Includes: one THX9321R Programmable touchscreen thermostat, one C7089R-1013/U wireless outdoor sensor, and one REM5000R-1001/U personal comfort control

RedLINK compatible - 2 heat and 2 cool stages for conventional systems - 3 heat and 2 cool stages for heat pumps - Automatic or manual changeover

Honeywell

Item SKU - YTHX9321R-5061/U

EDP - 915419

Case Quantity - 4

Out of stock

Old Number YTHX9321R-5003 and YTHX9321R-1000

Includes: one THX9321R-5030/U Programmable touchscreen thermostat, one C7089R-1013/U wireless outdoor sensor, and one REM5000R-1001/U portable comfort control

RedLINK compatible - 2 heat and 2 cool stages for conventional systems - 3 heat and 2 cool stages for heat pumps - Automatic or manual changeover

Honeywell

Item SKU - F76S1023

EDP - 840624

Out of stock

High flow capacity water filter used to remove sediment and debris from residential or commercial water systems

Whole House Protection - Ideally suited for sediment removal applications that would quickly plug and restrict the flow of normal filters.

Used as a prefilter, the F76 protects elements of the water system, including specialized treatment devices or other common fixtures and appliances.

The flow filtering capacity and ease of cleaning make the F76S ideal for the most demanding applications - 100 Micron screen

Built-in secondary filter provides an uninterrupted supply of filtered water during backwashing - 1 MIPS or 1 inch sweat union connections

Honeywell

Item SKU - AM101C-1/U

EDP - 319162

Out of stock

Old Number AM101C-1

Operating Temperature from 80 Degrees to 120 Degrees - 3/4 inch FIPS - Teflon Coated, Nickle Plated Brass Body

Teflon Coated Brass Shuttle - EPDM Rubber "O" Rings

Honeywell

Item SKU - AQ25044B/U

EDP - 870256

Out of stock

Old Number AQ2504B4 and AQ25044B

Zoning Control for up to four zones of four wire valves with end switches. Can be expanded to

a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones by using

up to three AQ254 Add-A-Temperature expansion panels and additional expansion zoning modules

Controls one boiler loop - Zone synchronization through Zone of Greatest Demand control

Domestic hot water priority and priority override protection - Use with digital thermostats

Honeywell

Item SKU - ARD12/U

EDP - 333655

Out of stock

Old Number ARD12

Honeywell Automatic Round Damper power-close, spring-open models ensure low leakage while controlling circulating air in heating, cooling and ventilation systems.

Features galvanized steel with single-blade damper, which closes off tightly against gasket for minimal leakage

Can be field-converted when used as an idependent zone or for fresh air intake

Honeywell

Item SKU - ARD14/U

EDP - 333654

Out of stock

Old Number ARD14

Honeywell Automatic Round Damper power-close, spring-open models ensure low leakage while controlling circulating air in heating, cooling and ventilation systems.

Features galvanized steel with single-blade damper, which closes off tightly against gasket for minimal leakage

Can be field-converted when used as an idependent zone or for fresh air intake

Honeywell

Item SKU - T822K-1018/U

EDP - 825130

Out of stock

Old Number T822K-1018

For low voltage control of single stage heating - Snap acting bimetal switch - Vertical mounting

Single pole, single throw (SPST) switching - Vented cover for improved temperature sensing

Setting lever and thermometer scale on thermostat face - Mounts directly on the wall or on vertical outlet box

Integrated thermometer and setting scale

Honeywell

Item SKU - C7061A-1020/U

EDP - 974052

Out of stock

Old Number C7061A-1020

For use with R7861 Dynamic Self Check Amplifier

Oscillating shutter interrupts ultraviolet radiation reaching the UV sensor to provide the UV sensor tube checking function.

Can be mounted horizontally, vertically or at any angle in between.

The detector requires faceplate alignment and has integral locating reference points to assure proper operation of the shutter mechanism.

Field replaceable ultraviolet sensing tube and quartz viewing window.

Models with threaded conduit fitting and color-coded leadwires allow rapid electrical installation

Two detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.

Protective heat block built into mounting flange - 120 or 230 volt flame sensor

Honeywell

Item SKU - SPRD12/U

EDP - 720532

Out of stock

Old Number SPRD12

Single blade, steel barometric damper used to bypass excess air when majority of zone dampers are closed

Counter balanced weighted arm to control bypass air for zoned systems

Air pressure in duct system increases as zone dampers close, pushing the SPRD open automatically

Arm and weight both adjustable to control amount of air bypassed - Recommended for low pressure systems with less than 0.5 in. wc

For larger systems and tighter pressure control, use MARD damper and static pressure controller (SPC)

Honeywell

Item SKU - L4103A1019/U

EDP - 228912

Case Quantity - 2

Out of stock

Old Number L4103A-1019

100 Degrees to 240 degrees - Single pole single throw - Breaks on temperature rise - Fixed differential - Includes 3/4 inch MIPS well

For water heaters - High limit - Totally enclosed Micro Switch snap-acting switches operate on temperature rise to setpoint.

Visible control point scale and external adjustment screw permit easy setting - Horizontal mounting

Honeywell

Item SKU - W8835A-1004/U

EDP - 824772

Out of stock

Old Number W8835A-1004

Use with VisionPRO IAQ Thermostats or FocusPRO communicating thermostats - Expandable to nine zones with additional W8703 Damper Interface Modules and Thermostats

Compatible with conventional gas, oil, electric or heat pump systems up to 3H/2C - Unsurpassed ease of wiring with only three wires to connect between devices

True communicating system using standard thermostat wire

Networked zoning enables these features: Time synchronization, Selectable high and low equipment protection settings, Adjustable purge timing and damper positions

Telephone remote access when used with optional W8735D Telephone Access Modules - Uses Zone of Greatest Demand Intelligence to reduce system cycling

Honeywell

Item SKU - AM101-1/U

EDP - 303332

Out of stock

Old Number AM101-1

Operating Temperature from 70 Degrees to 145 Degrees - 3/4 inch FIPS connections - Teflon Coated, Nickle Plated Brass Body

Teflon Coated Brass Shuttle - EPDM Rubber "O" Rings

Honeywell

Item SKU - AQ25A42B/U

EDP - 988313

Out of stock

Old Number AQ25A42B

Zoning Control for up to four zones of circulators or 2 wire zone valves. Can be expanded to

a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones by using

up to three AQ254 Add-A-Temperature expansion panels and additional expansion zoning modules

Domestic hot water priority and priority override protection - Use with digital thermostats

Honeywell

Item SKU - YTH9421C-1002/U

EDP - 824007

Case Quantity - 12

Out of stock

Old Number YTH9421C-1002

Includes: one TH9421C-1004/U VisionPRO IAQ Programmable Thermostat and one THM5421C-1008/U Equipment Interface Module

3 heat and 2 cool stages for conventional units - 4 heat and 2 cool stages for heat pumps - Automatic or manual changeover

Humidification control with or without Frost Protection - Dehumidification using whole house dehumidifier or air conditioning with high or low speed fan - Advanced ventilation Control - Advanced dual fuel heat pump control

Honeywell

Item SKU - THM5421C-1008/U

EDP - 824003

Out of stock

Old Number THM5421C-1008

Used with TH9421 thermostat

Advanced dual-fuel control - Three wires to the living space allows for easy equipment upgrade without having to run additional thermostat wire.

Controls temperature, humidification, dehumidification and ventilation from a single point in the home.

Automatically raises humidity levels throughout all rooms in the home

Removes air pollutants by exchanging the stale air in a house with fresh, filtered air

Honeywell

Item SKU - T451B-3004/U

EDP - 838620

Out of stock

Old Number T451B-3004

Controls line voltage valves, motors, contractors, electric heat, elements, duct furnaces, and fan coil units in heating systems

Includes vertical scaleplate and high accuracy Dual Diaphragm sensor - Less thermometer

Single pole, single throw (SPST) - Breaks on temperature rise - Positive off - Champagne gold face plate with beige cover

Honeywell

Item SKU - V4044B-1314/U

EDP - 734012

Out of stock

Old Number V4044B-1314

All models may be installed without disassembling the valve - Compact construction for easy installation - Normally closed - Manual opener

Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system

Motor may be replaced without removing the valve body or draining the system

Honeywell

Item SKU - SPRD14/U

EDP - 391096

Out of stock

Old Number SPRD14

Single blade, steel barometric damper used to bypass excess air when majority of zone dampers are closed

Counter balanced weighted arm to control bypass air for zoned systems

Air pressure in duct system increases as zone dampers close, pushing the SPRD open automatically

Arm and weight both adjustable to control amount of air bypassed - Recommended for low pressure systems with less than 0.5 in. wc

For larger systems and tighter pressure control, use MARD damper and static pressure controller (SPC)

Honeywell

Item SKU - ARD7/U

EDP - 376050

Out of stock

Old Number ARD7

Honeywell Automatic Round Damper power-close, spring-open models ensure low leakage while controlling circulating air in heating, cooling and ventilation systems.

Features galvanized steel with single-blade damper, which closes off tightly against gasket for minimal leakage

Can be field-converted when used as an idependent zone or for fresh air intake

Honeywell

Item SKU - PV100S/U

EDP - 703417

Out of stock

Old Number PV100S

1/2 inch Sweat connection size - 1 inch Sweat pipe size

Purges air through a no clog vent assembly, to control dirt and debris and minimize air vent fouling in Hydronic heating systems, while eliminating the need for bleeding.

No clog vent - Dirt and Debris resistant - 360 degree adjustable collar ring for installation flexibility - Stainless steel concentrator which eliminates gurgling noise

Bronze body for rigid construction.

Honeywell

Item SKU - TG510D1005/U

EDP - 673259

Out of stock

Old Number TG510D-1005

Outside Height: 5 7/8 inch - Outside Width: 5 11/16 inch

Depth: 2 7/16 inch

Inside Height: 4 7/16 inch - Inside Width: 4 7/16 inch

Unique double wall construction provides extra measure of tamper resistance - Used in both new and existing applications.

Tamper resistant lock; key cannot be removed unless in locked position - All models mount vertically or horizontally on wall or exposed junction box.

Vents in guard base allow airflow for optimum thermostat performance.

Honeywell

Item SKU - VS820M1309/U

EDP - 1043541

Out of stock

Old Number VS820M-1309

Includes manual gas valve, safety shutoff, millivolt automatic operator, remote rod adapter knob, one 3/4 inch x 1/2 inch bushing, one 1/2 inch x 3/8 inch bushing, and an LP conversion kit

Single stage - 750 millivolt - Standard Opening - 335,000 BTU per hour at 1 inch water column - 34,000 BTU per hour minimum - 425,000 BTU per hour maximum

Easy to install, adjust and service; all adjustments and connections are accessible from top of control

Complete safety shutoff on pilot flame failure - LITE-RITE (OFF-PILOT-ON) lighting sequence

Honeywell

Item SKU - ARD6/U

EDP - 389796

Out of stock

Old Number ARD6

Honeywell Automatic Round Damper power-close, spring-open models ensure low leakage while controlling circulating air in heating, cooling and ventilation systems.

Features galvanized steel with single-blade damper, which closes off tightly against gasket for minimal leakage

Can be field-converted when used as an idependent zone or for fresh air intake