Old Number POPUP1620
Fits F100 and F200 FiltersMERV 11
Contact our sales team for more information 860-221-SALE
Search results for
Relevant Product Categories
Old Number POPUP1620
Fits F100 and F200 FiltersMERV 11
Old Number R8285B-1053
Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or air conditioning circuits - Includes transformer - Double pole, double throw (DPDT) switching
Provides overload protection for transformer - Low voltage termnal board provides convenient connections for thermostat and heating and cooling equipment wiring
Relay is easily replaced without disturbing wiring - Mounts on standard 4 x 4 junction box - 120 Volt, 208 Volt, or 240 Volt
Old Number SV9501M-2528
SmartValve gas valve is suitable for a wide range of gas fired appliances including residential furnaces, roof top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units.
Ignition sequence includes timed trial for ignition - Includes LP conversion kit and extension harness
Old Number VR8200A-2132
Includes safety shutoff, manual valve, two automatic operators, pressure regulator, pilot adjustment, one 3/4 inch straight flange, one 1/2 inch x 3/8 inch bushing, and a Natural Gas to LP Conversion Kit
Single stage - 24 Volt - Standard Opening - 130,000 BTU per hour at 1 inch water column - 20,000 BTU per hour minimum - 200,000 BTU per hour maximum
Easy to install, adjust and service; all adjustments and connections are accessible from top of control
Provides two automatic valves: Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends - Diaphragm operated second automatic valve opens under control of regulator and closes if gas or power supply is interrupted
Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure
Meets codes requiring dual safety shutoff - Complete safety shutoff on pilot flame failure - LITE-RITE (OFF-PILOT-ON) lighting sequence
Old Number V8043E-1079
All models may be installed without disassembling the valve - Compact construction for easy installation - Normally closed - Manual opener - Single pole, single throw (SPST) end switch
Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
Motor may be replaced without removing the valve body or draining the system
Old Number YTH5320R-1000
Includes: one TH5320R-1002/U Wireless FocusPRO Non-Programmable Thermostat, one C7735A-1000/U Return Air Sensor, and one THM5320R-1000/U Equipment Interface Module
RedLINK compatible - 2 heat and 2 cool stages for conventional systems - 3 heat and 2 cool stages for heat pumps - Automatic or manual changeover
Old Number TG511A-1000
Outside Height: 6-1/2 inch - Outside Width: 7-1/2 inch
Depth: 2-15/16 inch
Inside Height: 5-1/16 inch - Inside Width: 6-1/16 inch
Unique double wall construction provides extra measure of tamper resistance - Used in both new and existing applications.
Tamper resistant lock; key cannot be removed unless in locked position - All models mount vertically or horizontally on wall or exposed junction box.
Vents in guard base allow airflow for optimum thermostat performance.
Old Number 394800-30
Fits S8600 Series
Old Number AQ25542B
Allows the addition of 4 zones of circulators, or 2, 2 wire zone valves to AQ2000 series boiler control panels
Old Number VR8345Q-4563
For use with direct spark ignition, hot surface ignition or intermittent pilot ignition
Includes manual valve, two automatic operators, pressure regulator, pilot adjustment, pilot plug, ignition adapter, two 3/4 inch x 1/2 inch bushings, and an LP conversion kit
Two stage - 24 Volt - Standard Opening - 300,000 BTU per hour at 1 inch water column - 30,000 BTU per hour minimum - 415,000 BTU per hour maximum
Easy to install, adjust and service; all adjustments and connections are accessible from top of control
Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/HSI jumper - Internal inlet screen blocks contaminants in gas line from entering valve
Old Number VR8215T-1502
Includes manual valve, two automatic operators, pressure regulator, and an LP conversion kit
Single stage - 24 Volt - Slow Opening - 150,000 BTU per hour at 1 inch water column - 15,000 BTU per hour minimum - 200,000 BTU per hour maximum
Easy to install, adjust and service; all adjustments and connections are accessible from top of control
Provides two automatic valves: Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends - Diaphragm operated second automatic valve opens under control of regulator and closes if gas or power supply is interrupted
Meets codes requiring dual safety shutoff - Complete safety shutoff on pilot flame failure - ON-OFF lighting sequence
Old Number R8182H-1070
Immersion type aquastat controller and oil burner primary control - Provides high limit and low limit/circulator control for oil fired hydronic heating systems
Use in intermittent ignition applications - Capable of zone control with zone valves - Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay
If restart is unsuccessful, safety shutoff occurs, and requires manual reset before burner can be restarted - Mounts horizontally on 4x4 junction box - Includes 5 foot armored capillary and heat conductive compound - Less well
Old Number CPRD12
1400 CFM Maximum airflow - This constant pressure regulating damper is a round static pressure relief damper. It is used in
forced air bypass applications to relieve excess static pressure when some of the zone dampers are closed
Can be installed in any orientation
Old Number R4222D-1021
Provides general purpose switching for refrigeration and air conditioning equipment, appliances, vending machines and similar applications
Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation.
Untaped coil assures cooler operation - Laminated magnet construction for higher efficiency - Double pole, double throw (DPDT) switching
Base designed for easy replacement of competitive relays - Plug compatible with Steveco 90-340 and Mars 90340.
Includes: Silicon carbide igniter, bracket, screw, 5-1/4 inch lead, and wiring accessories to adapt the igniter to the specific appliance application
Wiring Terminal Type: Receptacle with .093 inch male pins
Connection Type: Receptacle with .093 inch male pins
Designed to provide a robust field service replacement igniter in gas fired appliances with 120 VAC silicon carbide hot surface igniters
Uses a 120 volt silicon carbide igniter design with long life and high resistance to damage or burn out in the appliance - Natural Gas or LP
Old Number Q327A-1626
Includes mounting bracket style "B", A26 and K14 orifice's
Primary aerated, spud orifice type pilot burner for main burner ignition - Bat Wing tip style
Variety of tip directions to provide desired flame pattern - Interchangeable color coded orifices can be ordered to convert between natural and LP gas
Old Number ZD20X12TZ
Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.
Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades
Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24 volt spring return motor
Fail safe, normally open operation
Old Number ZD12X20TZ
Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.
Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades
Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24-volt spring return motor.
Fail safe, normally open operation
Acts as a splitter for applications that do not include a 24 volt C wire (common wire)
Fits THX9000 Series Thermostats
Old Number Q348U-1009
Includes: NE22, KF24, A26, KR14 orifices, Universal mounting bracket, ceramic insulated Kanthal flame rod with spark igniter and ground strap.
1 inch Batwing style hood - Can be converted to LP with orifice change
Old Number V8043E-1004
All models may be installed without disassembling the valve - Compact construction for easy installation - Normally closed - Manual opener - Single pole, single throw (SPST) end switch
Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
Motor may be replaced without removing the valve body or draining the system
Old Number FV180
150 PSI maximum operating pressure - 240 degrees maximum temperature
High temperature polypropylene float - 3-1/4 inches high - 1-27/32 inches diameter
For use with VNT5150H-1000, VNT5150E-1000, VNT5200H-1000 and VNT5200E-1011 heat recovery ventilators - Adjustable for 20 minutes, 40 minutes or 60 minutes
For use with HM750 series electrode steam humidifier
Used for six zones with zone valves, and includes a priority zone control - Compatible with most thermostats - "C" terminal is available for every thermostat connection - LED display panel is visible and functional whether the cover is on or off - Labels are coded to the wire colors
Used for three zones with circulators, and includes a priority zone control - Compatible with most thermostats - "C" terminal is available for every thermostat connection - LED display panel is visible and functional whether the cover is on or off - Labels are coded to the wire colors
Provides low voltage control of line voltage fan motors - For single or two speed fans - Mounts on standard 4 inch x 4 inch junction box
Old Number TRN1727T1
Higher efficiency and lower pressure drop than OEM filter - Captures particles as small as 0.3 microns - Pleated filter for greater media capacityLow pressure drop reduces strain on equipment, provides a comfortable air flow, and helps maintain equipment efficiency.
Easy installation because angled edge fits neatly into offset side of air cleaner frame - MERV 10
Old Number MX128LF
Manages the hot and cold supply based on control settings. Accurate control of temperature provides energy savings, increased comfort and safety. The Teflon wear surfaces prevent calcium buildup
Dual purpose mixing or diverting valve - Constant water temperature under different operating conditions.
Proportional valve (control of hot and cold water) - Flow reduction in seconds if cold water supply is interrupted.
Maintains temperature with extremely low minimum flows - Temperature adjustable, tamper evident.
Install in any position, heat trapping not required - Recirculation connection for fast response - Bronze/stainless construction.
Wear surfaces are Teflon coated to prevent deposit build up - Union/tailpiece connections included - Allen wrench for temperature adjustment included
Old Number F200F-2010
Uses 20 inch x 25 inch x 4 inch media - MERV 13 - 2000 CFM maximum air flow capacity
High efficiency media filter captures particles as small as 0.3 microns - Applicable to all gas, oil and electric forced air furnaces
and to compressor cooling up to 5 tons - Mounts in the return air duct - Rugged zinc coated, roll formed cabinet resists corrosion
and can support weight of residential furnace and evaporator coil - Requires no electrical connections - Mounts in any position
Requires no maintenance except periodic media filter replacement - Quick and easy media filter replacement
Later upgrade to higher performing media or electronic air cleaner is easy
Old Number 393691
Fits VR82xx Series and VR83xx Series
Includes: Regulator Spring, "O" Ring, Adjustment Screw, and Cap Screw
Old Number ZD8X24TZ
Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.
Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades
Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24 volt spring return motor
Fail safe, normally open operation
Old Number ZD22X8TZ
Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.
Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades
Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24 volt spring return motor
Fail safe, normally open operation
Old Number ZD18X12TZ
Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.
Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades
Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24 volt spring return motor
Fail safe, normally open operation
Old Number ZD10X24TZ
Power close and spring open damper - 24 volt motor used to control circulating air in HVAC systems and used when a normally open damper is required.
Mechanical visual position indicator for damper status - Solid construction using extruded aluminum frame and blades
Parallel blade design for low leakage performance - Simple, easy to wire, two wire installation - Reliable, strong, 24-volt spring return motor.
Fail safe, normally open operation
Old Number ARD9TZ
Honeywell Automatic Round Damper power-close, spring-open models ensure low leakage while controlling circulating air in heating, cooling and ventilation systems.
Features galvanized steel with single-blade damper, which closes off tightly against gasket for minimal leakage
Can be field-converted when used as an idependent zone or for fresh air intake
Old Number FC200E-1029
Fits F100 and F200 FiltersMERV 13
Includes: one THX9421R-5021WW/U Programmable touchscreen thermostat, one THM5421R-1021/U equipment interface module, one C7089R-1013/U wireless outdoor sensor, and two duct sensors
3 heat and 2 cool stages for conventional systems - 4 heat and 2 cool stages for heat pumps - Automatic or manual changeover
Control heating, cooling and IAQ equipment with only 2 wires at the thermostat - Heating, cooling and IAQ equipment wires to the Equipment Interface Module
Smart Schedule programs in seconds for any lifestyle - Interview based programming and installer setup - RedLINK wireless communication
Selectable for residential and light commercial applications - Meets commercial code and is title 24 compliant
Light commercial or commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day
Delta T Alerts and Diagnostics informs customers when their system is not performing as expected with instructions to contact the dealer - Comes standard with a return and discharge air temperature sensor to measure Delta T.
Alerts and User Interactions Log that keeps a searchable history of alerts and setting changes to the thermostat to determine if there is a system malfunction or if the issue was caused by user error
Performance Logs that keeps a history of heating and cooling performance - The performance log includes Minimum and Maximum Delta T, Minimum and Maximum Discharge Temperature, Minimum and Maximum Return Temperature, Minimum and Maximum Indoor Temperature/Humidity, Minimum and Maximum Outdoor Temperature/Humidity and Run Time
Customizable Service Reminders allow dealers to remind their customers when its time to call for service, when their warranty is expiring and to provide customized alerts
USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats or for adding the dealer's full color business logo on the screen
3 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling - 4 assignable inputs on the Equipment Interface Module can be used with wired outdoor, indoor or discharge sensors, occupancy sensor for remote setback and dry contact devices to trip pre-packaged or custom alerts
Extend wireless range of the Equipment Interface Module by connecting a THM4000R1000 Wireless Adapter (sold separetly) to the ABCD terminals
Old Number MX129LF
Manages the hot and cold supply based on control settings. Accurate control of temperature provides energy savings, increased comfort and safety. The Teflon wear surfaces prevent calcium buildup
Dual purpose mixing or diverting valve - Constant water temperature under different operating conditions.
Proportional valve (control of hot and cold water) - Flow reduction in seconds if cold water supply is interrupted.
Maintains temperature with extremely low minimum flows - Temperature adjustable, tamper evident.
Install in any position, heat trapping not required - Recirculation connection for fast response - Bronze/stainless construction.
Wear surfaces are Teflon coated to prevent deposit build up - Union/tailpiece connections included - Allen wrench for temperature adjustment included
Old Number VR8300C-4506
Includes safety shutoff, manual valve, two automatic operators, pressure regulator, pilot adjustment, and two 3/4 inch x 1/2 inch bushings - LP conversion kit is not available
Single stage - 24 Volt - Step Opening - 200,000 BTU per hour at 1 inch water column - 30,000 BTU per hour minimum - 300,000 BTU per hour maximum
Easy to install, adjust and service; all adjustments and connections are accessible from top of control
Provides two automatic valves: Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends - Diaphragm operated second automatic valve opens under control of regulator and closes if gas or power supply is interrupted
Meets codes requiring dual safety shutoff - Complete safety shutoff on pilot flame failure - LITE-RITE (OFF-PILOT-ON) lighting sequence
Old Number AM102R-US-1
Operating Temperature from 70 Degrees to 180 Degrees - 1 inch Sweat Unions - Teflon Coated, Nickle Plated Brass Body
Teflon Coated Brass Shuttle - EPDM Rubber "O" Rings
Old Number TRN2621T1
Higher efficiency and lower pressure drop than OEM filter - Captures particles as small as 0.3 microns - Pleated filter for greater media capacityLow pressure drop reduces strain on equipment, provides a comfortable air flow, and helps maintain equipment efficiency.
Easy installation because angled edge fits neatly into offset side of air cleaner frame - MERV 10
Old Number Y8610U-4001
Converts atmospheric standing pilot systems to intermittent pilot on gas boilers and furnaces
Includes: VR8204A-2142/U 1/2 inch gas valve, ignition module, pilot burner hardware, ignition cable, and wiring harness
Can be used with Natural or LP gas - Provides 100 percent pilot gas shutoff if pilot fails to light; after 6 minute delay, trial for ignition is repeated
Ignition trail and delay sequence is repeated until the appliance lights or call for heat is removed
Old Number YTH6320R-1001
Includes: one TH6320R-1004/U Wireless FocusPRO Programmable Thermostat, one C7735A-1000/U return air sensor, and one THM5320R-1000/U Equipment Interface Module - RedLINK compatible - 2 heat and 2 cool stages for conventional units - 3 heat and 2 cool stages for heat pumps - Automatic or manual changeover
Old Number AQ25042B
Zoning Control for up to four, single stage zones or two, two stage zones. Can be expanded to
a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones by using
up to three AQ254 Add-A-Temperature expansion panels and additional expansion zoning modules
Controls one boiler loop - Zone synchronization through Zone of Greatest Demand control
Domestic hot water priority and priority override protection - Use with digital thermostats