This check kit includes the parts necessary to repair or replace the first or second check of a 1 1/2 to 2 inch double check valve assembly, series 805 and 825YD. All parts are genuine and original to the valve.
Febco® Single Check Kit, For Use With: Model 825GBV/825HBV 1-1/2 to 2 in Double Check Valve Assembly, Import
This HY-420 wall hydrant repair kit consists of a bronze complete internal assembly and loose key. It is a non-freeze assembly.
WATTS® Wall Hydrant Repair Kit, For Use With: Series HY-420 Non-Freeze Key Operated Wall Hydrant, Bronze, Import
This 1/2 and 3/4 in 800M4 check repair kit provides all the parts necessary to repair the check of the applicable pressure vacuum breaker. This kit includes the check disc assembly, bonnet O-ring and check spring. All parts are genuine and original to the valve.
WATTS® Check Kit, For Use With: Model 800M4QT 1/2 to 3/4 in Lead Free Anti-Siphon Pressure Vacuum Breaker, Domestic
This 3/4 in 009M3 second check repair kit provides all the parts necessary to replace the major internal components of the applicable reduced pressure zone assembly. The check kit consists of the check assembly and cover O-ring. All parts are genuine and original to the valve.
WATTS® Second Check Kit, For Use With: Model 009/LF009 3/4 in Reduced Pressure Zone Assembly, Domestic
This 3/4 in 009M3 total relief valve repair kit is used to repair the designated backflow preventer. The kit consists of seat, seat O-ring, stem and diaphragm assembly, stem O-ring and cover O-ring relief valve spring. All parts are genuine and original to the valve.
WATTS® Total Relief Valve Kit, For Use With: Model 009/LF009 3/4 in Reduced Pressure Zone Assembly, Domestic
This 3/4 x 3/4 inch high capacity safety relief valve is designed for pressure cookers and steam cleaning equipment with low pressure requirements. It features a bronze body with an extended inlet shank, stainless steel spring, top guided stem, NPT threaded male inlet x threaded female outlet (drain) connection, and a non-stick PTFE(R) disc to metal seating ensures positive shutoff. The factory pressure setting for saturated steam service is set at 8 psi.
WATTS® Safety Relief Valve, Series: 315M2-015, 3/4 in Nominal, MNPT x FNPT, 8 psi, Media: Steam, Bronze Body, Bronze Seat, 2-3/4 in H
WATTS® Drainage WD Series PDI Certified recessed or floor mounted epoxy coated steel grease interceptor with gasketed epoxy coated steel skid-proof cover secured with hex head center bolts, removable baffle assembly, deep seal trap with cleanout, external cast iron flow control fitting, and no hub (standard) connections.
WATTS® Grease Interceptor, Series: WD Series, 2 in Inlet Connection, 2 in Outlet, 8 lb Capacity, 4 gpm, Steel, 16 in L x 10 in W x 11 in H, Import
This 3/4 inch lead free dual check vacuum breaker backflow preventer with atmospheric vent prevent high-hazard backsiphonage backflow and low-head backpressure (10 FT or less) from contaminating the potable water supply. It prevents backflow associated with hose connections when screwed directly to a sill cock, yard hydrant, or wall hydrant. It consists of a lead free brass body with two independently operating rubber and stainless steel check valves, with an atmospheric vent located between the them. It is in-line field testable, non-removable and designed for non-continuous pressure applications. It is ideal for installation in service sinks, chemical dispensers, sill cocks, and frost proof hydrants. Maximum working pressure is 125 psi (10.6 bar).
WATTS®, 0792099, Backflow Preventer, Inline, Series: LFN9, 3/4 in Nominal, Female Hose Threaded x Male Hose Threaded End Style, 125 psi Pressure, 180 deg F, 4 gpm Flow Rate, Double Check Backflow, Media: Water, Brass Body, Chrome, 2-13/16 in H x 1-1/2 in W Dimensions, Import
This 1-1/2 through 2 in lead-free lever handle replacement kit is constructed of stainless steel material and is used on backflow preventers. This handle kit consists of a lever handle with a vinyl insulator. The handle should be replaced with the manufacturer's original part to ensure proper fit and accurate function. All parts are genuine and original to the valve.
WATTS® Replacement Handle Kit, For Use With: Backflow Preventer, Stainless Steel, Import
This 1/2 in lead free small water pressure regulator is used in small general purpose applications to regulate water pressure in piping systems using water and #2 fuel oil. It has an oversized orifice and is ideally used on beverage dispensing and paint spraying equipment, ice cube machines, humidifiers, drinking fountains and other small process applications. It consists of a lead free brass body with an adjusting tee handle, FNPT connections, two-way low water pressure gauge port, aluminum spring cage, Buna-N stainless steel disc and a reinforced Buna-N diaphragm. The reduced water pressure range is 1 to 25 psi. It is factory set at 10 psi.
WATTS® Pressure Regulator, 2-Way Small, Series: LF26A, 1/2 in Nominal, FNPT End Style, 300 psi Pressure, 0 to 140 deg F, Media: Water, T-Handle Actuator, 2-1/8 in Inlet to Outlet Length, Brass Body, Stainless Steel Trim, Buna-N® Diaphragm Softgoods, 4-3/8 in H Dimensions, Domestic
Series 340, 340X Automatic Reseating Temperature and Pressure Relief Valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature a bronze body with NPT male inlet and NPT female outlet connections, stainless steel spring and thermostat tube, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model 340 has a 3 in. (80mm) thermostat. Model 340X has an 8 in. (200mm) thermostat. Series 340, 340X are ASME rated and CSA listed. Temperature Relief: 210 deg F (99 deg C), Pressure Relief Range: 75 to 150psi (5.2 to 10.3 bar), Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar).
WATTS® Temperature/Pressure Relief Valve, Automatic Reseating, Series: 340, 1-1/2 in Nominal, MNPT x FNPT, 150 psi, 210 deg F, Media: Water, Bronze Body, 4-1/2 in W x 9-3/4 in H, Domestic
The WATTS® SD2 is a dual check designed for the protection of the water supply from carbon dioxide gas and carbonated water. These substances can flow from post-mix beverage systems and are very acidic. If the acidic water comes in contact with copper tubing or copper pipe, it will cause the leaching of copper salts into the water supply. The dissolved copper if ingested can cause nausea, abdominal pain and in some cases vomiting. The SD-2 prevents the reverse flow of potentially contaminated water into the potable water supply due to back pressure backflow and is used for continuous or intermittent pressure conditions. The WATTS® SD-2 is recommended for use on Post-Mix Carbonated Beverage Equipment and dispensing equipment for tea and coffee.
WATTS®, 0061663, Dual Check Valve, Series: SD-2, 3/8 in Nominal, FNPT End Style, 200 psi Pressure, 110 deg F, 316 Stainless Steel Body, 3 in L Dimensions, Domestic
Series 740 Boiler Pressure Relief Valves are used in hot water space heating boiler applications to protect against excessive pressure on all types of hot water space heating boiler equipment. It consists of a iron body construction with expanded outlet drain connections for hot water space heating boilers, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 740 offers large discharge capacity, resists corrosive water conditions, resists sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control. Pressure Range: 30 to 75psi (2 to 5 bar) with corresponding high ratings from 925,000 to 10,700,000 BTU/hr.
WATTS®, 0382870, Pressure Relief Valve, Series: 740, 1 in Nominal, FNPT End Style, 60 psi Pressure, 250 deg F, Media: Water, Iron Body, Domestic
This 3/4 in two-way straight pattern universal flow check valve is for use in commercial and residential hydronic heating systems to provide positive shutoff when circulator is not running, preventing the flow of water to radiation units. It is easily opened for gravity circulation. It combines angle and horizontal checks and consists of an iron body construction with female threaded connections, bronze seat, and brass center guide. The maximum pressure is 50 PSI (344.8kPa). The maximum pressure is 125 PSI (8.6 BAR).
WATTS®, 0856763, Flow Check, 2-Way Straight, Series: 2000S-M5, 3/4 in Nominal, Socket End Style, 50 psi Pressure, 3 in Inlet to Outlet Length, Bronze Body, 3-5/8 in H Dimensions, Domestic
This 3/4 inch 2-piece full port lead free ball valve is used in commercial and industrial applications for a full range of liquids and gases. It features a lead free brass body, bottom-loaded blowout proof stem, virgin PTFE seat, thrust washer, adjustable stem packing gland, stem packing nut, chrome plated lead free brass ball, cap and chain, lead free brass adapter and steel handle. The pressure rating is 600 psi WOG and 150 psi WSP.
This 1-1/4 in lead free cast copper silicon water pressure reducing valve for low pressure ranges is designed to reduce incoming water pressure to protect plumbing systems and reduce water consumption for commercial, industrial and residential applications. The easy maintenance assembly consists of a replaceable seat module, FNPT union inlet by FNPT outlet and a bypass feature to control thermal expansion pressure. The temperature range is 33 to 160 deg F. The low pressure range is 10 to 35 psi with the standard setting at 30 psi.
WATTS®, 0009373, Pressure Reducing Valve, Standard Capacity, Series: LF25AUB-Z3, 1-1/4 in Nominal, FNPT Union x FNPT End Style, 10 to 35 psi Pressure, 33 to 160 deg F, Media: Water, Copper Silicon Alloy Body, EPDM Diaphragm Softgoods, 9 in H Dimensions, Domestic
Series 174A Boiler Pressure Relief Valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet (drain) connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control. Standard Pressure Setting: 30psi (206.9 kPa), Pressure Range: In 5psi (34.5 kPa) increments from 30 to 150psi (2 to 10 bar) with corresponding high ratings from 650,000 to 14,370,000 BTU/hr.
WATTS®, 0278034, Pressure Relief Valve, Series: 174A, 2 in Nominal, FNPT End Style, 40 psi Pressure, 250 deg F, Media: Water, Bronze Body, 6-1/2 in L x 11-1/2 in H Dimensions, Domestic
This 1/2 in anti-siphon vacuum breaker hot or cold water repair kit, for series 288A-Z1, prevents the reverse flow of polluted water from entering into the potable water supply due to back siphonage. It consists of a disk and disc float, a bonnet and O-Ring. It has a full size orifice to assure pipe size capacity and maximum flow. It is ideal for low flow, non-continuous hot or cold water health hazard installations such as on laboratory equipment. Maximum Pressure is 125 psi.
WATTS® Repair Kit, For Use With: Series 288A-Z1 1/2 in Anti-Siphon Vacuum Breaker, Domestic
Series 40L, 40XL Automatic Reseating Temperature and Pressure Relief Valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature a bronze body with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model 40L has a short thermostat for installation directly in available tank tapings. Model 40XL has an extension thermostat for installation in the hot water outlet within the allowable distance from the top of the tank. Series 40L, 40XL valves are ASME rated and CSA listed. Temperature Relief: 210 deg F (99 deg C), Pressure Range: 75 to 150psi (5.2 to 10.3 bar), Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar).
WATTS®, 0153109, Temperature/Pressure Relief Valve, Automatic Reseating, Series: 40L, 3/4 in Nominal, MNPT x FNPT End Style, 125 psi Pressure, 125 lb Pressure Class, 210 deg F, Media: Water, Bronze Body, Domestic
This seat kit is used to repair or replace the seat on a 4 inch lead free double check valve assembly used to prevent the reverse flow of polluted water from entering into the potable water supply. This kit consists of a seat and a seat O-ring, retainer wire and a cover O-ring. It is ideal at referenced cross-connections identified in non-health hazard applications.
This fourth check valve kit is used to repair or replace the fourth check valve on a 4 inch lead free double check valve assembly and used to prevent the reverse flow of polluted water from entering into the potable water supply. This kit consists of a disc and spring assembly and a cover O-ring. It is ideal at referenced cross-connections identified in non-health hazard applications.
This 1-1/4 through 2 in 009M1 total repair kit provides all the parts necessary to replace the major internal components of the applicable reduced pressure zone assembly. This kit consists of first and second check valve assemblies and relief valve assembly. All parts are genuine and original to the valve.
WATTS® Total Repair Kit, For Use With: Model 009/LF009 1-1/4 to 2 in Reduced Pressure Zone Assembly, Domestic
Series 174A Boiler Pressure Relief Valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet (drain) connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control. Standard Pressure Setting: 30psi (206.9 kPa), Pressure Range: In 5psi (34.5 kPa) increments from 30 to 150psi (2 to 10 bar) with corresponding high ratings from 650,000 to 14,370,000 BTU/hr.
WATTS®, 0276771, Pressure Relief Valve, Series: 174A, 1-1/2 in Nominal, FNPT End Style, 80 psi Pressure, 250 deg F, Media: Water, Bronze Body, 4-3/4 in L x 9-1/4 in H Dimensions, Domestic
This 3/4 inch IPFX-T is a full port isolation pump valve which features a swivel flange and threaded end connections. This flanges allows for the installer to position the handle of the valve in an optimal orientation for use.
This 1/2 IN lead free anti-siphon, spill resistant, vacuum breaker backflow preventer prevents the reverse flow of polluted water from entering into the potable water supply due to backsiphonage on indoor point-of-use applications. It consists of an internal polymer coating, bronze body construction, thermoplastic check and float assembly valve, stainless steel springs, tee handles, and a molded diaphragm separating the air inlet from the potable water supply to prevent spillage. It is ideal for indoor use on machines or equipment in general plumbing applications. Maximum working pressure is 150 psi (10.34 bar). Minimum working pressure is 8 psi (55.2 kPa).
Series LF777SI, LFS777SI Lead Free brass wye-pattern strainers feature a wye-pattern, lead Free brass body stainless steel screen and solid tapped retainer cap with NBR gasket. Model LF777SI comes with threaded connections and is available in sizes 3/8 to 3 in (10 to 80mm). Model LFS777SI comes with solder connections and is available in sizes 1/2 to 2 in. (15 to 50mm). Model LF777SI - maximum pressure (non shock): 400psi at 210 deg F WOG, 125 psi at 353 deg F WSP. Model LFS777SI - maximum pressure (non shock): 400 psi at 150 deg F 15 psi at 250 deg F WSP.
WATTS® Wye Strainer, Series: LF777SI, 3/4 in Nominal, 3-3/16 in Overall Length, FNPT, 1/4 in NPT Blow-Off, EPDM, Cast Copper Silicon Alloy Body, Import
This 4 IN complete rubber parts kit for series 709 helps to prevent the reverse flow of polluted water from entering into the potable water supply. This kit consist of two disc and two cover O-rings. It is ideal at referenced cross-connections identified in non-health hazard applications. Check with local inspection authorities for installation requirements.
This relief valve repair kit includes the parts necessary to repair or replace the relief valve of a 1-1/2 to 2 in reduced pressure zone assembly. All parts are genuine and original to the valve.
Febco® Relief Valve Kit, For Use With: Model 825Y 1-1/2 to 2 in Y Pattern Design Reduced Pressure Zone Assembly, Import
This 2 inch Y pattern reduced pressure zone backflow preventer assembly prevents the reverse flow of high hazard (toxic) fluids found in the water from entering into the potable water supply due to backsiphonage and or backpressure. It is used in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants and is also used in irrigation systems, boiler feed, water lines and other installations requiring maximum protection. This assembly consists of a bronze body, threaded quarter turn ball valves, test cocks, spring loaded Y pattern check valves, and one hydraulically dependent differential relief valve. This backflow assembly contains a flood sensor with SentryPlus Alert(R) technology to detect excessive water discharges from the relief valve. When paired with an add on connection kit, the sensor is activated to relay alerts for potential flooding events. Connection kit options include BMS, cellular communication, and the Sensor Control Monitor which enables integration with BAS via RS-485 Modbus or the Nexa(R) platform through Wi-Fi.
Febco®, F825HBV, Backflow Preventer with Flood Sensor, Straight, Series: 825Y, 2 in Nominal, NPT End Style, 175 psi Pressure, 32 to 140 deg F, Quarter-Turn Ball Valve Ball Valve/Gate Valve, Reduced Pressure Zone Backflow, Media: Water, Rough Bronze, Import
Series 174A Boiler Pressure Relief Valves are used in hot water heating and domestic supply boiler applications to protect against excessive pressures on all types of hot water heating supply boiler equipment. It consists of a bronze body construction with NPT threaded female inlet and NPT threaded female outlet (drain) connections, non-metallic disc-to-metal seating, stainless steel spring, and test lever. Series 174A resists corrosive water conditions, sticking and freezing, and prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control. Standard Pressure Setting: 30psi (206.9 kPa), Pressure Range: In 5psi (34.5 kPa) increments from 30 to 150psi (2 to 10 bar) with corresponding high ratings from 650,000 to 14,370,000 BTU/hr.
WATTS®, 0278328, Pressure Relief Valve, Series: 174A, 2 in Nominal, FNPT End Style, 50 psi Pressure, 250 deg F, Media: Water, Bronze Body, 6-1/2 in L x 11-1/2 in H Dimensions, Domestic
This 1 in 919 total repair kit provides all the parts necessary to replace the major internal components of the applicable reduced pressure zone assembly. This kit consists of first check repair kit, second check repair kit and relief valve repair kit. All parts are genuine and original to the valve.
WATTS® Total Repair Kit, For Use With: Model 919/LF919 1 in Reduced Pressure Zone Assembly, Domestic
Series LF3001A Lead Free Dielectric Unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metals, and features a female iron pipe thread to solder connection. It consists of a union nut, two tailpieces, and a gasket that separates the tailpieces to prevent an electric current from occurring. Series LF3001A is ideal in applications such as hot water storage tanks, water and air conditioners, processing tanks, steam, gas, and water piping.
WATTS® Dielectric Union, 1 in Nominal, FNPT x Solder, 2-7/8 in Hex, 2-1/2 in Length, 250 psi, Brass, 180 deg F, Domestic
Series LF909 Reduced Pressure Zone Assemblies are designed to provide cross-connection control protection of the potable water supply in accordance with national plumbing codes. This series can be utilized in a variety of installations, including health hazard cross connections in plumbing systems or for containment at the service line entrance. With its exclusive relief valve design incorporating the "air-in/water-out" principle, it provides substantially improved relief valve discharge performance during the emergency conditions of combined backsiphonage and backpressure with both checks fouled. The LF909 features Lead Free construction to comply with Lead Free installation requirements.
WATTS®, 0122764, Reduced Pressure Zone Assembly, Series: LF909, 6 in Nominal, 175 psi Pressure, 33 to 110 deg F, Resilient Seated Gate Valve Ball Valve/Gate Valve, Cast Copper Silicon Alloy Body, Epoxy Coated, 65-1/2 in L Dimensions, Domestic
This cover repair kit consists of a cover and cover O-ring and is used to repair or replace the cover on a 2 in lead free reduced pressure zone assembly used to prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure.
WATTS® Cover Kit, For Use With: Model 009 2 in Lead Free Reduced Pressure Zone Assemblies, Import
This 1/2 inch lead free water hammer arrestor provides economical and effective single fixture protection used in residential or domestic water applications such as dishwashers, washing machines, and quick closing faucets. It is designed to control the water pressure shock and prevent water hammer conditions that are damaging to pipes and appliances. It consists of a stainless steel top and lower chamber, sealed-in diaphragm which flexes to absorb the shock, and a lead free brass hex adapter for easy installation. This may be installed in new or existing plumbing systems vertically, horizontally or at any angle and should be installed as close to the shock source as possible, with one unit for each hot and cold water line up to 150 psi (10.6 bar) working pressure. It is factory air charged at 30 psi (207 kPa) and is easily rechargeable with a standard tire valve connection and air-tight sealing cap.
WATTS® Water Hammer Arrester, Series: LF150, 1/2 in Nominal, NPT, 150 psi, 180 deg F
Series LF263A Lead Free Small Pressure Regulators are used in small general purpose applications to regulate pressure in piping systems using water and No. 2 fuel oil. It consists of a Lead Free brass body construction with NPT threaded female inlet and outlet connections, 1/4 in. 3-way low-pressure gauge port, aluminum spring cage, Buna-N stainless steel disc, reinforced Buna-N diaphragm, and tee handle adjustment. Options include FKM trim and slotted adjusting screw. Strainers are recommended. Series LF263A has an oversized orifice and is ideal for use on beverage dispensing and paint spraying equipment, ice cube machines, humidifiers, drinking fountains, and other small process applications. Maximum Working Pressure: 300 psi (21 bar).
WATTS® Pressure Regulator, 3-Way Small, Series: LF263A, 1/2 in Nominal, FNPT End Style, 300 psi Pressure, 0 to 140 deg F, Media: Water, T-Handle Actuator, 2-1/8 in Inlet to Outlet Length, Brass Body, Buna-N Stainless Steel Trim, 4-3/8 in H Dimensions, Domestic
This lead free 1/2 in bypass control relief valve is used in commercial, residential and in residential applications to regulate liquid pressure as supplied by a positive pressure pump. This is a poppet-type compact valve that protects equipment by opening at the desired setting to allow excess volume to be by-passed back to the source. It consist of a lead free brass body construction with MNPT inlet and FNPT outlet, PTFE.
WATTS® By-Pass Control Relief Valve, Automatic Reseating, 1/2 in Nominal, MNPT x FNPT End Style, 0 to 250 psi Pressure, Spring-Loaded Latch-Lock Handle Actuator, Brass Body, Domestic
Series LFB6400 2-Piece, Standard Port, Lead Free Ball Valves are used in commercial and industrial applications for a full range of liquids and gases. It comes standard with actuator mounting pads. The LFB6400 standard port orifice ensures minimal pressure drop, while Durafill seats, blow-out proof pressure retaining stem and stainless steel ball provide lasting service.
WATTS® Ball Valve, 2-Piece, 1/2 in Nominal, 600 psi Pressure, -55 to 450 deg F, Standard Port, Media: Gas/Liquids, 1/2 in Orifice, 316 Stainless Steel Ball, 2-1/4 in Inlet to Outlet Length, 1-3/4 in Top to Inlet Center, Bronze Body, 316 Stainless Steel Stem and PTFE Durafill® Seat Trim, PTFE Softgoods, Domestic