DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE -
If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE -
If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water
content - Beckett AFG oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base
section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE -
If boiler is fired at .85 gallons per hour: 119,000 BTU input - 104,000 BTU heating capacity - 86.2% AFUE -
If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 126,000 BTU heating capacity - 85.0% AFUE - 12 gallons water content -
Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section
design - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE -
If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE -
If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water
content - Beckett AFG oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base
section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .95 gallons per hour: 133,000 BTU input - 117,000 BTU heating capacity - 87.0% AFUE -
If boiler is fired at 1.25 gallons per hour: 175,000 BTU input - 154,000 BTU heating capacity - 87.1% AFUE -
If boiler is fired at 1.50 gallons per hour: 210,000 BTU input - 183,000 BTU heating capacity - 86.1% AFUE - 14.75 gallons water
content - Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base
section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE -
If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE -
If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water
content - Carlin EZ1HP oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base
section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE -
If boiler is fired at .85 gallons per hour: 119,000 BTU input - 104,000 BTU heating capacity - 86.2% AFUE -
If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 126,000 BTU heating capacity - 85.0% AFUE - 12 gallons water content -
Carlin EZ1HP oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section
design - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off
DOE 2021 compliant - If boiler is fired at .60 gallons per hour: 84,000 BTU input - 75,000 BTU heating capacity - 87.5% AFUE -
If boiler is fired at .85 gallons per hour: 119,000 BTU input - 105,000 BTU heating capacity - 87.1% AFUE -
If boiler is fired at 1.05 gallons per hour: 147,000 BTU input - 127,000 BTU heating capacity - 86.0% AFUE - 11.75 gallons water
content - Carlin EZ1HP oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base
section design - Taco 007 circulator - Full plate swing out burner door - Top or Rear flue outlet - Built in air elimination baffle
If boiler is fired at 1.75 gallons per hour: 245,000 BTU input - 212,000 BTU heating capacity - 85.5% AFUE -
If boiler is fired at 1.95 gallons per hour: 273,000 BTU input - 235,000 BTU heating capacity - 85.0% AFUE - 17.75 gallons water content -
Beckett oil burner - Cast iron sections with steel push nipples - Insulated deluxe powder coated steel jacket - Wet base section
design - Full plate swing out burner door - Top flue outlet - Built in air elimination baffle - Boiler reset control with low water cut off