The Taco 007 is a cartridge style, maintenance free, wet-rotor, in-line, single stage circulator pump. It is designed for quiet operation in Indirect water heaters, chilled fresh water and domestic water recirculation systems. The unique replaceable cartridge contains all of the moving parts and allows the circulator to be easily serviced instead of replacing the entire unit. Ideal for a wide range of applications.
Search results for
All Products
Relevant Product Categories
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
The Taco 009 with integral flow check is designed for a wide range of residential and light commercial higher-head / lower-flow water circulating applications. Typical uses include hydronic heating, radiant in-floor/panel heating and closed-loop solar heating systems. The unique replaceable cartridge contains all of the moving parts and allows for easy service, instead of replacing the entire circulator. Compact, direct-drive, low power consumption design is ideal for high-efficiency jobs. Self lubricating - No mechanical seal - Universal flange dimensions
The Taco 0010-F3-IFC with integral flow check is designed for a wide range of large residential and light commercial water circulating applications. Typical uses include hydronic heating, radiant in-floor/panel heating and primary-secondary loops. The unique replaceable cartridge contains all of the moving parts and allows for easy service, instead of replacing the entire circulator. Compact, direct-drive, low power consumption design is ideal for high-efficiency jobs. Self lubricating - No mechanical seal - Universal flange dimensions
The Taco 006 is designed for circulating hot or chilled fresh water in open or closed loop applications. Typical uses include hydronic heating, domestic hot water recirculation, hydro-air heating/cooling, heat recovery units, water source heat pumps, drain down open loop Solar systems and potable water applica-tions. The unique, replaceable cartridge contains all of the moving parts and allows for easy service instead of replacing the entire circulator. The compact, low power consumption design is ideal for high efficiency jobs.
Taco Zone Sentry zone valves provide on/off, normally closed control in closed hydronic systems. The unique patented technology in the Zone Sentry utilizes a microcircuit based logic to control a gear driven electronic actuator which drives a ball valve based body design. The valves can be used in a wide variety of heating and condensing cooling applications, primarily designed for use with baseboad, fan coils, radiators, convectors, air handlers, heat pumps and radiant applications.
Taco Heat Motor Zone Valves provide a convenient way to create individual zones or equipment isolation in a hydronic heating system. Utilizing one pump along with multiple zone valves, flow can be started, stopped, or diverted through the system to provide individual room or area comfort control and energy savings. Includes manual open lever.
Taco QuickTop Zone Valves provide on/off, normally closed control in closed hydronic systems. The valves can be used in a wide variety of heating & cooling applications. Use with baseboard, fan coils, radiators, convectors, air handlers, heat pumps and radiant applications.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
The Taco 007 is a cartridge style, maintenance free, wet-rotor, in-line, single stage circulator pump. It is designed for quiet operation in Hydronic heating, Radiant heating. The unique replaceable cartridge contains all of the moving parts and allows the circulator to be easily serviced instead of replacing the entire unit. Ideal for a wide range of applications.
Fits 5120-2, 5120-2-G, 5000-3, and 5000-3-G - Set of 3 is for one valve
Fits 110, 117, and HC cast iron circulators
Old Number 110-251BF
Fits 003, 005, 006, 007, 007e, 008, 009, 0010, 0011, 0013, 0014, 0015, 0015e, 0018e, 110, 111, 112, 113, 2400-10, 2400-20, 2400-45, and 2400-50
Compact, space saving design - Powerful close-coupled, maintenance free motor - Superior efficiency, high starting torque - Permanently lubricated, sealed for life bearings - Rugged 1/2" Stainless Steel Shaft - Carbon/Silicon-Carbide mechanical seal for long life - Universal flange to flange dimensions; Ideal for retrofits - Anti-Condensate design for chilled water - Dual electrical knock-outs - Dual pressure taps, suction and discharge
The Taco 0010 is designed for a wide range of large residential and light commercial water circulating applications. Typical uses include hydronic heating, radiant in-floor/panel heating and primary-secondary loops. The unique replaceable cartridge contains all of the moving parts and allows for easy service, instead of replacing the entire circulator. Compact, direct-drive, low power consumption design is ideal for high-efficiency jobs. Self lubricating - No mechanical seal - Universal flange dimensions
Resilient mounted, split phase motor with built-in overload protector - Equipped with sleeve bearings for quiet operation - One piece non-ferrous impeller - Stainless steel shaft - Rugged bronze sleeve bearing - Two piece carbon/ceramic seal assembly - Durable one piece spring coupling - Every circulator is operated before shipment
Automatic multispeed switching - Prevents false calls for fan operation - Simplified wiring - Contractor friendly PC board layout - Built in time delays - Pump exercise timer - 100% Factory tested - The Hydro Air Fan Control is an interface between the thermostat and air handler. It also has an isolated end switch to start the boiler and/or pump. When the thermostat calls for heat, the Fan Control energizes the end switch relay and allows the fan to operate at low speed when the water is above the optional aquastat setting. When the thermostat calls for cooling, the Fan Control energizes the condenser and operates on high speed. The Fan Control also includes three built in fan time delay options, two selectable pump exercise modes, a secondary aquastat connection for freeze protection and the ability to switch a pump and / or boiler.
Fits 5120-2, 5120-2-G, 5000-3, and 5000-3-G - Set of 3 is for one valve
The Taco SmartPlug is designed to upgrade any hot water recirculation system. SmartPlug replaces inefficient timers and aquastats typically used in recirculation systems. It adds intelligence to your system by learning when hot water is used in the home. The pipe- mounted temperature sensor records daily hot water usage patterns during the course of a week. Recorded data is used to automatically run the circulator at the same times the following week. So hot water is always available when it's needed. If usage pattern changes, the SmartPlug adjusts automatically.
Front diagnostic lights - Switchable priority - Built in priority protection - Simplified wiring - Works with 2, 3, or 4 wire zone valves - Compact design - Fuse protected - 100% Factory tested - Two pump end switches can control up to 3 pumps; system, secondary and DHW - Contractor friendly PC board layout - Universal thermostat compatibility - 24 volt power output for hard wired thermostats - Field replaceable transformer - Add on power control plug - Built in post purge and pump exercise functions - Two boiler contacts - Expandable to 20 zoning panels (120 zones if all are 6 zone panels - Interface with EXP switching relays - UL approved
Taco Flo-Cheks are used in a forced hot water heating system to prevent gravity circulation during periods when the boiler is hot but the space heating zone is not wanted. This makes it possible for the use of the heating boiler to maintain domestic hot water year round. In systems with multiple circulator zones, Flo-Cheks allow heat to flow only into the zones that are calling for heat. Also, the thumb screw can be manually opened for gravity feed appplications if the main circulator stops operating
Fits 5120-2, 5120-2-G, 5000-3, and 5000-3-G - Set of 3 is for one valve
Fits 0012-F4-1 and 2400-50/2
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
The 0014-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with 00 circulators on medium head / medium flow hydronic or radiant heating, hydro-air fan coils or closed loop solar heating systems. By locating the removable, spring-loaded IFC inside the pump casing, a separate in-line flow check is eliminated, reducing installation costs. The reduced pressure drop of the IFC, increases the flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit.
Fits 5120-2, 5120-2-G, 5000-3, and 5000-3-G - Set of 3 is for one valve
Fits cast iron or bronze 110, 111, 112, 113, 117, and 120 through 120-13
The Taco 009 is designed for a wide range of residential and light commercial higher-head / lower-flow water circulating applications. Typical uses include hydronic heating, radiant in-floor/panel heating and closed-loop solar heating systems. The unique replaceable cartridge contains all of the moving parts and allows for easy service, instead of replacing the entire circulator. Compact, direct-drive, low power consumption design is ideal for high-efficiency jobs. Self lubricating - No mechanical seal - Universal flange dimensions
Fits B&G 60-2 and 60-11 - B&G part number 118473 - Fits B&G PD-37, PD-35, 60-14, and 60-13 - B&G part number 118709 - Fits Armstrong H-51 and H-52 - Armstrong part numbers 810120-003 and 807436-000 - Fits Armstrong S-57, S-55, H-54, and H-53 - Armstrong part numbers 806137-000 and 810120-006
The Taco 0012 is specifically designed for high flow/medium head applications in large residential and light commercial systems. Ideal for large BTUH Boilers, 2" recirculation loops, Primary/Secondary loops, commercial water heaters and light commercial heating and cooling systems. The unique replaceable cartridge contains all of the moving parts and allows for easy service instead of replacing the entire circulator. Universal flange to flange dimensions and orientation allows the 0012 to easily replace other models. Compact, low power consumption design makes it ideal for high-efficiency jobs. The 0012-F4 is a direct replacement for the HV Series
The Taco Hy-Vent has become the industry standard for dependable long life service. The high capacity float style vents can be placed either on the boiler or at the high points throughout the system. Now with operating pressure ratings of up to 250 PSI, the brass body, nickel plated vents meet the system requirements of even the largest installation. The vents are also easily serviceable if needed, by just unscrewing the vent cap.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
The Taco 008 is designed for a wide range of residential and light commercial higher-head circulating applications. Typical uses include hydronic heating, radiant in-floor/panel heating and closed-loop solar heating systems. The unique replaceable cartridge contains all of the moving parts and allows for easy service, instead of replacing the entire circulator. Compact, direct-drive, low power consumption design is ideal for high-efficiency jobs. Self lubricating - No mechanical seal - Universal flange dimensions
Front diagnostic lights - Switchable priority - Built in priority protection - Simplified wiring - Premium sealed relays - Compact design - Fuse protected - 100% Factory tested - Isolated end switch - Contractor friendly PC board layout - Universal thermostat compatibility - 24 volt power output for hard wired thermostats - Field replaceable transformer - UL Approved
The Taco 4900 Series Air Separators are designed for the complete elimination of air from closed loop heating and cooling systems up to a maximum temperature of 240 F and a maximum pressure of 150 psi. The principle on which the Taco 4900 Series Air Separator is based is a patented and proven method of removing gases from water: the PALL ring process. Minimal pressure loss - Vent can be closed - Large surface contact area - Protective vent plate - Maximum air removal - Expansion tank connection tapping - No minimum run of pipe requirement - Bi-directional flow
The Taco 0010 is designed for a wide range of large residential and light commercial water circulating applications. Typical uses include open loop fresh water systems. The unique replaceable cartridge contains all of the moving parts and allows for easy service, instead of replacing the entire circulator. Compact, direct-drive, low power consumption design is ideal for high-efficiency jobs. Self lubricating - No mechanical seal - Universal flange dimensions
The Taco 008 Stainless Steel circulator can be used in higher-head heat recovery, water source heat pump,open-loop solar heat and domestic water recirculation systems. The unique replaceable cartridge contains all of the moving parts and allows for easy service, instead of replacing the entire circulator. Compact, direct-drive, low power consumption design is ideal for high-efficiency jobs. Self lubricating - No mechanical seal - Universal flange dimensions
Taco Flo-Cheks are used in a forced hot water heating system to prevent gravity circulation during periods when the boiler is hot but the space heating zone is not wanted. This makes it possible for the use of the heating boiler to maintain domestic hot water year round. In systems with multiple circulator zones, Flo-Cheks allow heat to flow only into the zones that are calling for heat. Also, the thumb screw can be manually opened for gravity feed appplications if the main circulator stops operating
Taco Heat Motor Zone Valves provide a convenient way to create individual zones or equipment isolation in a hydronic heating system. Utilizing one pump along with multiple zone valves, flow can be started, stopped, or diverted through the system to provide individual room or area comfort control and energy savings. Includes manual open lever.