Mixing Valves 78
Adjustable thermostatic and pressure balanced mixing valve - 85 degree to 150 degree setting range - 75 PSI maximum operating differential pressure - 20 PSI maximum recommended differential pressure - 200 degree maximum hot water inlet temperature - The 521 series three way thermostatic mixing valve is used in systems producing domestic hot water or in hydronic and radiant heating systems. It maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
Old Number MX129LF
Manages the hot and cold supply based on control settings. Accurate control of temperature provides energy savings, increased comfort and safety. The Teflon wear surfaces prevent calcium buildup
Dual purpose mixing or diverting valve - Constant water temperature under different operating conditions.
Proportional valve (control of hot and cold water) - Flow reduction in seconds if cold water supply is interrupted.
Maintains temperature with extremely low minimum flows - Temperature adjustable, tamper evident.
Install in any position, heat trapping not required - Recirculation connection for fast response - Bronze/stainless construction.
Wear surfaces are Teflon coated to prevent deposit build up - Union/tailpiece connections included - Allen wrench for temperature adjustment included
Adjustable - Female union inlet connections - Press union outlet connections - 95 degree to 150 degree setting range - 75 PSI maximum dynamic working pressure - 150 PSI maximum static working pressure - 195 degree maximum hot water inlet temperature - The TankMixer combines a three way thermostatic mixing valve with a cold water cross and flexible pipe for easy installation directly on a typical gas fired water heater and other water heaters that now comply with the National Appliance Energy Conservation Act (NAECA). The TankMixer maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water. The mixing valve hot inlet port closes tight to prevent temperature creep in recirculation applications. The angle style body design offers improved fluid dynamics for better performance and reduces installation labor and materials, eliminating a piping elbow in typical installations.
Dual purpose mixing or diverting valve - Teflon wear surfaces - 145 degree maximum temperature
Old Number AMX101-US-1LF
Operating Temperature from 70 Degrees to 145 Degrees - 3/4 inch Sweat Unions - Teflon Coated, Stainless Steel/Brass Body
Designed to be Directly Installed on Water Heater Outlet Port - EPDM Rubber "O" Rings - Check Valves on Hot and Cold Ports
Old Number AM102R-US-1
Operating Temperature from 70 Degrees to 180 Degrees - 1 inch Sweat Unions - Teflon Coated, Nickle Plated Brass Body
Teflon Coated Brass Shuttle - EPDM Rubber "O" Rings
Old Number MX128LF
Manages the hot and cold supply based on control settings. Accurate control of temperature provides energy savings, increased comfort and safety. The Teflon wear surfaces prevent calcium buildup
Dual purpose mixing or diverting valve - Constant water temperature under different operating conditions.
Proportional valve (control of hot and cold water) - Flow reduction in seconds if cold water supply is interrupted.
Maintains temperature with extremely low minimum flows - Temperature adjustable, tamper evident.
Install in any position, heat trapping not required - Recirculation connection for fast response - Bronze/stainless construction.
Wear surfaces are Teflon coated to prevent deposit build up - Union/tailpiece connections included - Allen wrench for temperature adjustment included
Adjustable thermostatic and pressure balanced mixing valve - 85 degree to 150 degree setting range - 75 PSI maximum operating differential pressure - 20 PSI maximum recommended differential pressure - 200 degree maximum hot water inlet temperature - The 521 series three way thermostatic mixing valve is used in systems producing domestic hot water or in hydronic and radiant heating systems. It maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water.
This versatile NSF 61, ASSE 1017, ASSE1070 mixing valve provides the ultimate performance for domestic hot water applications. The 5120 Series ASSE1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater, kill harmful bacteria and still be delivered at a safe 120 F or less. The ASSE 1070 listing allows for point of use applications within homes, hospitals, schools, nursing homes, public facilities, etc. where a 1070 valve is required.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
Adjustable thermostatc and pressure balanced mixing valve - 85 degree to 150 degree setting range - 75 PSI maximum operating differential pressure - 20 PSI maximum recommended differential pressure - 200 degree maximum hot water inlet temperature - The 521 series three way thermostatic mixing valve is used in systems producing domestic hot water or in hydronic and radiant heating systems. It maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water.
This 1/2 inch lead free thermostatic mixing valve is designed for residential, commercial or institutional environments for supplying baths or lavatories with tempered water. The double throttling design controls both hot and cold water supply to the mixed outlet. It consists of a lead free brass body, solder union connections, solid wax hydraulic principle thermostat, integral filter washers and check valves with a locking mechanism for the temperature setting. The adjustable field range temperature at mixed outlet is 80 to 120 degrees F (27 to 49 degrees C). The maximum pressure rating is 150 psi
Dual purpose mixing or diverting valve - Teflon wear surfaces - 145 degree maximum temperature
Old Number AM100-US-1LF
Operating Temperature from 100 Degrees to 145 Degrees - 1/2 inch Sweat Unions - Teflon Coated, Nickle Plated Lead Free Brass Body
Teflon Coated Lead Free Brass Shuttle - EPDM Rubber "O" Rings
Old Number AMX300TLF
Operating Temperature from 33 Degrees to 212 Degrees - 3/4 inch FIPS - Teflon Coated, Nickel Plated Lead Free Brass Body
Teflon Coated Lead Free Brass Shuttle - Designed to be Directly Installed on Water Heater Outlet Port - EPDM Rubber "O" Rings - Check Valves on Hot and Cold Ports
Includes: 1 - Mixing Valve, 1 - Cold Water Tee, and 1 - 8 inch Flexible Connector
This 1/2 inch hot water extender mixing valve is designed for domestic water supply systems and recommended for tankless heater, water heater, and solar applications installed at or near the boiler or hot water heater. It consists of a lead free brass body, solder connections, thermostat, stainless steel springs, and dial adjustment cap. The hydraulically operated thermostat opens a spring loaded check in the cold water inlet which allows cold and hot water to mix and can be replaced as a unit. The temperature range is 120 to 160 degrees F (49 to 71 degrees C).
Adjustable thermostatic and pressure balanced mixing valve - 85 degree to 150 degree setting range - 75 PSI maximum operating differential pressure - 20 PSI maximum recommended differential pressure - 200 degree maximum hot water inlet temperature - The 521 series three way thermostatic mixing valve is used in systems producing domestic hot water or in hydronic and radiant heating systems. It maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
This versatile NSF 61, ASSE 1017, ASSE1070 mixing valve provides the ultimate performance for domestic hot water applications. The 5120 Series ASSE1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater, kill harmful bacteria and still be delivered at a safe 120 F or less. The ASSE 1070 listing allows for point of use applications within homes, hospitals, schools, nursing homes, public facilities, etc. where a 1070 valve is required.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
Adjustable - Female union inlet connections - Press union outlet connections - 95 degree to 150 degree setting range - 75 PSI maximum dynamic working pressure - 150 PSI maximum static working pressure - 195 degree maximum hot water inlet temperature - The TankMixer combines a three way thermostatic mixing valve with a cold water cross and flexible pipe for easy installation directly on a typical gas fired water heater and other water heaters that now comply with the National Appliance Energy Conservation Act (NAECA). The TankMixer maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water. The mixing valve hot inlet port closes tight to prevent temperature creep in recirculation applications. The angle style body design offers improved fluid dynamics for better performance and reduces installation labor and materials, eliminating a piping elbow in typical installations.
Adjustable - Female union inlet connections - Sweat union outlet connections - 95 degree to 150 degree setting range - 75 PSI maximum dynamic working pressure - 150 PSI maximum static working pressure - 195 degree maximum hot water inlet temperature - The TankMixer combines a three way thermostatic mixing valve with a cold water cross and flexible pipe for easy installation directly on a typical gas fired water heater and other water heaters that now comply with the National Appliance Energy Conservation Act (NAECA). The TankMixer maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water. The mixing valve hot inlet port closes tight to prevent temperature creep in recirculation applications. The angle style body design offers improved fluid dynamics for better performance and reduces installation labor and materials, eliminating a piping elbow in typical installations.
This hot water extender mixing valve is designed for domestic water supply systems and recommended for tankless heater, water heater, and solar applications installed at or near the boiler or hot water heater. It consists of a lead free brass body, threaded connections thermostat, stainless steel springs, and dial adjustment cap. The hydraulically operated thermostat opens a spring loaded check in the cold water inlet which allows cold and hot water to mix and can be replaced as a unit. The temperature range is 120 to 160 degrees F (49 to 71 degrees C).
Dual purpose mixing or diverting valve - Teflon wear surfaces - 145 degree maximum temperature
Old Number AM101-US-1LF
Operating Temperature from 70 Degrees to 145 Degrees - 3/4 inch Sweat Unions - Teflon Coated, Nickle Plated Lead Free Brass Body
Teflon Coated Lead Free Brass Shuttle - EPDM Rubber "O" Rings
Dual purpose mixing or diverting valve - 0.5 GPM minimum flow - EPDM "O" rings - 212 degree maximum temperature
Dual purpose mixing or diverting valve - Teflon wear surfaces - 145 degree maximum temperature
Adjustable thermostatc and pressure balanced mixing valve - 85 degree to 150 degree setting range - 75 PSI maximum operating differential pressure - 20 PSI maximum recommended differential pressure - 200 degree maximum hot water inlet temperature - The 521 series three way thermostatic mixing valve is used in systems producing domestic hot water or in hydronic and radiant heating systems. It maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
Adjustable thermostatic mixing valve - 95 degree to 150 degree setting range - 75 PSI maximum dynamic working pressure - 150 PSI maximum static working pressure - 195 degree maximum hot water inlet temperature - The 520 series three way thermostatic mixing valve is used in systems producing domestic hot water. It maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water.
Adjustable thermostatic and pressure balanced mixing valve - 85 degree to 150 degree setting range - 75 PSI maximum operating differential pressure - 20 PSI maximum recommended differential pressure - 200 degree maximum hot water inlet temperature - The 521 series three way thermostatic mixing valve is used in systems producing domestic hot water or in hydronic and radiant heating systems. It maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
This versatile mixing valve provides the ultimate performance for domestic hot water applications. The 5000 Series ASSE 1017 certification allows for domestic hot water storage at temperatures high enough to increase the effective storage capacity of a water heater kill harmful bacteria and still be delivered at a safe 120 F or less. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85 - 176 F range.
This 3/8 inch under sink guardian lead free thermostatic mixing valve is used in commercial and residential applications to control the hot water temperature and minimize the potential for accidental scalding. It is suitable for kitchen and bath installations where the water delivered to the fixtures is intended for bathing or washing. The double throttling design controls both the hot and cold water supply to the mixed outlet. This valve consists of a lead free brass body, 3/8 inch male compression fittings, copper thermostat, check valves, integral strainer with 40 mesh stainless steel screens, and a tamper resistant locking cap. The maximum working pressure is 150 psi. The water temperature can be field adjusted between 80 to 120 degrees F (27 to 49 degrees C). The recommended maximum temperature is 110 degrees F
Adjustable - Female union inlet connections - Male union outlet connections - 95 degree to 150 degree setting range - 75 PSI maximum dynamic working pressure - 150 PSI maximum static working pressure - 195 degree maximum hot water inlet temperature - The TankMixer combines a three way thermostatic mixing valve with a cold water cross and flexible pipe for easy installation directly on a typical gas fired water heater and other water heaters that now comply with the National Appliance Energy Conservation Act (NAECA). The TankMixer maintains the desired output temperature of the mixed water supplied at a constant set value compensating for both temperature and pressure fluctuations of the incoming hot and cold water. The mixing valve hot inlet port closes tight to prevent temperature creep in recirculation applications. The angle style body design offers improved fluid dynamics for better performance and reduces installation labor and materials, eliminating a piping elbow in typical installations.